MIL-HDBK-103AP
4.6 Electrostatic discharge sensitivity (ESD) listing. ESD classification levels, as required by MIL-PRF-38534 or
MIL-PRF-38535, will be listed in the status column of section 1, part 1, of the appendix. Manufacturers are required to send
these classification levels to DLA Land and Maritime-VA for all Standard Microcircuit Drawings for which they are an approved
source. The ESD listing in section 1, part 1 of the appendix will be in accordance with the following:
STATUS
Blank
0
1
1A
1B
1C
2
3
3A
3B
INTERPRETATION
Data not submitted
Class 0; < 250 V
Class 1; 0 – 1999 V
Class 1A; 250 V – 499 V
Class 1B; 500 V – 999 V
Class 1C; 1,000 V – 1999 V
Class 2; 2000 V – 3999 V
Class 3; ≥ 4000 V
Class 3A; 4000 V – 7999 V
Class 3B; ≥ 8000 V
5. CONFIGURATION MANAGEMENT
5.1 Configuration management of SMDs. All proposed changes to existing SMDs will be coordinated with the military
activities and industry users of record for the individual documents. This coordination will be accomplished using DD Form
1693, Engineering Change Proposal (Short Form).
5.2 Record of users. Industrial users should inform DLA Land and Maritime when a system application requires use of the
SMD. When notified, DLA Land and Maritime will maintain a record of users and this list will be used for coordination and
distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should contact
DLA Land and Maritime-VAC, telephone (614) 692-8108.
3