CBW SERIES
Up to 30 Watts, DC/DC Power Converters
Rev D
SPECIFICATIONS: CBW SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
GENERAL SPECIFICATIONS
Efficiency
TEST CONDITIONS
Min
Typ
Max
Unit
Nominal input voltage and full load
Single & Dual output models
Triple output models
See Table
430
400
387
360
1600
1600
1600
1
473
440
Switching Frequency
kHz
Input to Output
Input to Case
Output to Case
Isolation Voltage
1 minute
500VDC
VDC
Isolation Resistance
GΩ
Isolation Capacitance
1500
pF
ENVIRONMENTAL SPECIFICATIONS
With derating
Without derating
-40
+50
+50
+85
Operating Ambient Temperature
°C
Maximum Case Temperature
Storage Temperature
+105
°C
°C
-55
5
+125
Natural convection
Natural convection with heatsink
12
10
Thermal Impedance (See Note 1)
Relative Humidity
°C/W
%
RH
95
Thermal Shock
Vibration
MIL-STD-810F
MIL-STD-810F
BELLCORE TR-NWT-000332 Case 1: 50% Stress, Ta=40°C
MIL-HDBK-217F Notice 2, Ta=25°C, full load (G/B, controlled environment)
BELLCORE TR-NWT-000332 Case 1: 50% Stress, Ta=40°C
3,163,000
434,700
2,904,000
318,400
Single & Dual Output Models
MTBF
hours
hours
Triple Output Models
MIL-HDBK-217F Notice 2, Ta=25°C, full load (G/B, controlled environment)
PHYSICAL SPECIFICATIONS
Weight
1.07oz (30.5g)
2.00 x 1.00 x 0.40 inch
(50.8 x 25.4 x 10.2 mm)
Dimensions (L x W x H)
Case Material
Base Material
Potting Material
Shielding
Nickel-coated copper
FR4 PCB
Epoxy (UL94-V0)
Six-sided
Connect case to –Input with
decoupling Y Cap
Case Grounding
SAFETY & EMC CHARACTERISTICS
Safety Approvals
IEC60950-1, UL60950-1, EN60950-1
Class A
EMI (See Note 4)
EN55022
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Air ±8kV and Contact ±6kV
Perf. Criteria A
Radiated Immunity
Fast Transient (See Note 5)
Surge (See Note 5)
Conducted Immunity
10 V/m
±2kV
Perf. Criteria A
Perf. Criteria A
±1kV
Perf. Criteria A
10 Vrms
Perf. Criteria A
NOTES
1. Heat sink is optional. To order the module with a heatsink please add the suffix “HS” to the model number (Ex: CBW24S12-2500HS).
2. Positive remote on/off control is standard; for negative remote on/off please add the suffix “R” to the model number (Ex: CBW24S12-
2500R).
3. Triple output models require a minimum loading on the output to maintain all specified regulations. Operation under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
4. The CBW series standard models can only meet EN55022 Class A and Class B with external components added.
5. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
- 24VDC nominal input models: Nippon chemi-con KY series, 330μF/50V
- 48VDC nominal input models: Nippon chemi-con KY series, 220μF/100V
CAUTION: This power converter is not internally fused. An input line fuse must always be used.
Due to advances in technology, specifications subject to change without notice.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-
11/29/2017
9797
Page 3 of 34
website: www.wallindustries.com • e-mail: sales@wallindustries.com