型号: SCL1700
PDF下载: 下载PDF文件 查看货源
内容描述: 测斜仪子组件 [Inclinometer Subassembly]
分类和应用:
文件页数/大小: 2 页 / 260 K
品牌: VTI [ VTI TECHNOLOGIES ]
 浏览型号SCL1700的Datasheet PDF文件第2页  
Preliminary
SCL1700 Series
Inclinometer Subassembly
FEATURES
• Available range:
±10
°
• DC…3 Hz sensing bandwidth (controlled frequency response)
• Easy to use and design in
• 0.001 ° resolution analogue output
• 0.2 ° accuracy
• Dual axis inclination measurement
• Advanced failure detection
BENEFITS
• Excellent long term stability
• Sensing element filtered high frequency vibration
• Outstanding shock durability
APPLICATIONS
• Platform tilt measurement
• Equipment and instrument condition monitoring
• Inclination based position measurement
For customized product please contact VTI Technologies
ELECTRICAL CHARACTERISTICS
Parameter
Supply voltage
Output load
Operating temperature
Mechanical shock
1 m drop on concrete
(1
Condition
Min
7
Typ.
15
4.5
T.B.D
T.B.D.
Max
28
Units
V
mA
kOhm
nF
Current consumption
Resistive
Capacitive
-40
85
20 000
°C
g
PERFORMANCE CHARACTERISTICS
Parameter
Measuring range
(1
Measuring axis
Offset
(2,3
Offset calibration error
(3,4
Offset temperature error
(3,5
Sensitivity
(3,6
Sensitivity calibration error
(3,7
Sensitivity temperature error
(3,8
Nonlinearity
(9
Frequency responce -3 dB
Output noise
DC...10 Hz
0…70 °C
-25…85 °C
0…70 °C
-25…85 °C
@ 0 ° (offset position)
(See “Directions”)
Output at 0 °
Condition
SCL1700-D01
±10
X-Y
2.5
±0.1
±0.2
±1
200
±1
±0.5
±1
±0.03
1...3
0.001
Units
°
V
°
°
°
mV/°
%
%
%
°
Hz
°
Typical values @ room temperature, 15 V supply unless otherwise specified.
Note 1.
Note 2.
Note 3.
Note 4.
Note 5.
Note 6.
The measuring range is limited by sensitivity, offset and supply voltage rails of the device.
Offset specified as Voffset = Vout(@0 °) [V].
+15 V supply voltage used in calibration and testing.
Offset calibration error specified as Offset_Calib_error = arcsin(Offset_Calib_error_in_g) [ ° ],
Offset_Calib_error_in_g = {Vout(@0 °) – 2.5 V} / Vsens [g], Vsens=11.46 V/g.
Offset temperature error specified as
Offset_Error_@_temp. = arcsin(Offset_Error_@_temp_in_g) [ ° ],
Offset_Error_@_temp_in_g = {Vout @ temp. – Vout @ room temp.} / Vsens [g], Vsens=11.46 V/g.
Sensitivity target in calibration Vsens _nom 11.46 V/g (--> 200 mV/°)
Sensitivity specified as Vsens = {Vout(@+10 °) - Vout(@+10 °)}/(2*sin(10 °) g) [V/g].
Note 7.
Note 8.
Note 9.
Sensitivity calibration error specified as
Sensitivity_calibr_error = {Vsens - Vsens_nom} / Vsens_nom x 100 % [%],
Vsens_nom = nominal sensitivity.
Sensitivity temperature error specified as
Sensitivity_temp_error = {Vsens @ temp – Vsens @ room temp} / Vsens @ room temp} x 100 % [%].
From best fit sine-function to output through –10 ° and +10 °.
Rev. 10 Sept 2004