 浏览型号SCA3000-E04-10的Datasheet PDF文件第5页浏览型号SCA3000-E04-10的Datasheet PDF文件第6页浏览型号SCA3000-E04-10的Datasheet PDF文件第7页浏览型号SCA3000-E04-10的Datasheet PDF文件第8页浏览型号SCA3000-E04-10的Datasheet PDF文件第10页浏览型号SCA3000-E04-10的Datasheet PDF文件第11页浏览型号SCA3000-E04-10的Datasheet PDF文件第12页浏览型号SCA3000-E04-10的Datasheet PDF文件第13页  
SCA3000 Series  
negative accelerations until a valid acceleration value is read. In Table 4 the maximum and  
minimum acceleration register values that are in measuring range (for registers X_LSB … Z_MSB)  
for SCA3000-D0x and SCA3000-E0x are presented.  
Table 4. Maximum and minimum values in the SCA3000 measuring range.  
SCA3000-D01  
SCA3000-D02  
SCA3000-E01  
SCA3000-E02  
-
SCA3000-E04  
SCA3000-E05  
First positive  
[mg]  
dec  
bin  
-
-
-
acceleration value  
out of range  
3072  
3072  
3072  
3072  
0110 0000 0000 0xxx  
2303.25 mg  
3071  
0110 0000 0000 0xxx  
3071 mg  
3071  
0110 0000 0000 0xxx  
6142 mg  
3071  
0110 0000 0000 0xxx  
19193.75 mg  
3071  
Maximum positive  
acceleration value  
in range  
[mg]  
dec  
bin  
0101 1111 1111 1xxx  
-2304 mg  
-3072  
0101 1111 1111 1xxx  
-3072 mg  
-3072  
0101 1111 1111 1xxx  
-6144 mg  
-3072  
0101 1111 1111 1xxx  
-19200 mg  
-3072  
Minimum negative [mg]  
acceleration value  
in range  
dec  
bin  
1010 0000 0000 0xxx  
1010 0000 0000 0xxx  
1010 0000 0000 0xxx  
1010 0000 0000 0xxx  
First negative  
acceleration value  
out of range  
[mg]  
dec  
bin  
-
-
-
-
-3073  
-3073  
-3073  
-3073  
1001 1111 1111 1xxx  
1001 1111 1111 1xxx  
1001 1111 1111 1xxx  
1001 1111 1111 1xxx  
2.3 Motion Detection Mode  
2.3.1 Description  
In MD mode, the ADC's data is not fed to the signal processing channel shown in Figure 1 but to  
the MD block. It consists of a digital band-pass filter (BPF), threshold level programmable digital  
comparator and a configurable trigger function.  
BPF's -3 dB low-pass frequency is 25 Hz …60 Hz and -3 dB high-pass frequency is  
0.05 Hz …1 Hz. See Figure 2 below.  
Band Pass Filter's Response  
for reference only  
5
0
-5  
Lower limit  
Upper limit  
-10  
-15  
-20  
0.01  
0.1  
1
10  
100  
1000  
Freq [Hz]  
Figure 2. The MD band-pass filter's frequency response.  
VTI Technologies Oy  