SCA3000 Series  
The absolute value of programmable Threshold Level (TL) is 0 < |TL| < FS g (FS is sensor full  
scale measuring range). NOTE: Due to power consumption optimization, the step size between  
each step and axis is not the same, see section 3.4 for threshold level details.  
The triggering condition can be defined using OR/AND logic:  
1. Any sensing direction can be configured to trigger the interrupt (OR condition).  
2. Any sensing direction can be configured to be required to trigger the interrupt (AND condition).  
Acceleration exceeds  
Acceleration  
the threshold level  
X, Y or Z  
due to motion  
+TL  
T1  
T2  
T3  
T4  
T5  
T6  
T7  
T8  
Time  
-TL  
INT output  
"1"  
"0"  
T1  
T2  
T3  
T4  
T5  
T6  
T7  
T8  
Time  
Figure 3. Motion detector operation.  
2.3.2 Usage  
The MD mode can be enabled by setting the MODE bits in the MODE register to "011". The trigger  
condition can be defined by setting REQ_Z, REQ_Y, REQ_X, EN_Z, EN_Y and EN_X bits in  
MD_CTRL register and Z_TH, Y_TH and Z_TH bits in MD_Z_TH, MD_Y_TH and MD_X_TH  
registers, respectively. See section 3.4 for the configuration register and section 2.7 for the  
interrupt functionality details.  
In MD mode, acceleration data is not available in registers X_LSB, X_MSB, Y_LSB, Y_MSB,  
Z_LSB, Z_MSB and BUF_DATA.  
2.3.3 Examples  
A simple example of motion detection usage:  
1. Write "00000011" (03h) into the MODE register (enable motion detection mode,  
MODE_BITS = '011').  
2. Acceleration data is not available when the SCA3000 is in motion detection mode.  
3. The INT-pin is activated when motion is detected, see section 2.7 for detailed INT-pin  
information.  
In the next example, the motion detector is configured to give an interrupt on motion only in the X-  
OR Y-axis direction:  
1. Write "00000011" (03h) into MODE register (enable motion detection mode,  
MODE_BITS = '011')  
2. Write "00000000" (00h) into UNLOCK register  
3. Write "01010000" (50h) into UNLOCK register  
4. Write "10100000" (A0h) into UNLOCK register  
Unlock sequence for register lock  
5. Write "00000010" (02h) into CTRL_SEL register (to select indirect MD_CTRL register)  
6. Write "00000011" (03h) into CTRL_DATA register (this data is written into MD_CTRL  
register, enable trigger on Y-channel, EN_Y = '1', enable trigger on X-channel, EN_X = '1')  
VTI Technologies Oy  
www.vti.fi  
10/ 43  
Rev.A.07  
Doc.Nr. 8257300A.07