 浏览型号CMA3000-D01DEMO的Datasheet PDF文件第2页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第3页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第4页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第5页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第7页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第8页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第9页浏览型号CMA3000-D01DEMO的Datasheet PDF文件第10页  
CMA3000-D0X Series
1.2.4
Supported features
Supported features are listed in Table 1 below.
Table 1. CMA3000-D0X devices’ summary.
Features
Supply voltage
I/O voltage
Measuring range (selectable)
Resolution (2g /8g range)
Sensitivity (2g /8g range)
Motion detection
Free fall detection
Interface
Clock
CMA3000-D01
1.7 V – 3.6 V
1.7 V – 3.6 V
±2 g, ±8 g
17 mg / 67 mg
56 counts/g / 14 counts/g
User enabled
User enabled
SPI max 500 kHz, I
2
C fast mode 400 kHz
Internal
1.2.5
1.2.5.1
Operation modes
Power Down
In Power Down (PD) mode device's volatile register keep their contents and the current
consumption is minimized. Power down mode is the default mode after start up.
1.2.5.2
Measurement
In Measurement mode (Meas) the sensor offers acceleration information via the digital SPI/I
2
C
interface. Interrupt can be activated via INT-pin, when each xyz-acceleration sample is ready to be
read.
Measurement range and sample rate are user selectable according to Table 2. Measurement mode
can be activated by detected motion.
1.2.5.3
Motion Detection
Motion Detection (MD) mode is intended to be used to save system level power consumption. In
this mode, CMA3000-D0X activates the interrupt via the INT-pin when motion is detected. Motion
sensitivity level can be configured via the SPI or I
2
C bus. Moreover, duration of the motion to be
detected can be user defined. Once the interrupt has happened, the detected direction can be read
out from the corresponding status register.
Low sample rate (10 Hz) band-pass filtered acceleration information is available in MD mode. The
device can be configured to switch automatically into the measurement mode with highest
sampling rate after motion detection.
1.2.5.4
Free-Fall Detection
Free-Fall Detection (FFD) is intended to be used to save system resources. This feature activates
the interrupt via the INT-pin when free-fall is detected. Acceleration information is available when
the FFD is enabled.
1.2.6
Interrupt
The CMA3000 has a dedicated output pin (INT) to be used as the interrupt for the master
controller. Interrupt conditions can be activated and deactivated via the SPI or I
2
C bus. Once the
interrupt has happened, the interrupt source can be read out from the corresponding status
register.