 浏览型号CMA3000-D01-30的Datasheet PDF文件第4页浏览型号CMA3000-D01-30的Datasheet PDF文件第5页浏览型号CMA3000-D01-30的Datasheet PDF文件第6页浏览型号CMA3000-D01-30的Datasheet PDF文件第7页浏览型号CMA3000-D01-30的Datasheet PDF文件第9页浏览型号CMA3000-D01-30的Datasheet PDF文件第10页浏览型号CMA3000-D01-30的Datasheet PDF文件第11页浏览型号CMA3000-D01-30的Datasheet PDF文件第12页  
CMA3000-D0X Series  
2
Reset and power up, Operation Modes, HW functions and Clock  
2.1 Reset and power up  
The CMA3000 has internal power-on reset circuit. It releases the internal reset-signal once the  
power supplies will be within the specified range.  
After releasing the internal reset, the CMA3000 will read configuration and calibration data from the  
non-volatile memory to volatile registers. Then the CMA3000 will make parity check to the read  
memory content. The STATUS register's PERR-bit="0" shows successful memory read operation.  
Device can be externally reset by writing the sequence 02h, 0Ah, 04h into the RSTR-register.  
2.2 Power Down mode  
The CMA3000-D0X enters the power down mode by default after power-on reset and initialization  
of the volatile registers. PD can also be set by writing MODE[2:0] = 000b (or MODE[2:0] = 111b) to  
CTRL register.  
Output registers will keep their content in the power down mode.  
2.3 Measurement Mode  
2.3.1 Description  
The CMA3000-D0X is set to a measurement mode by writing MODE[2:0] = 0XXb to CTRL register.  
Data will be reliable in the output registers after the product specific turn-on time.  
Default sample rate is 400 Hz (MODE[2:0] = 010b). Other data rates are 100 Hz (MODE[2:0] =  
001b) and 40 Hz (MODE[2:0] = 011b).  
Table 2. CMA3000-D0X measurement ranges and output sample rates  
Measurement range  
Output sample rates  
2 g  
8 g  
400 Hz, 100 Hz  
400 Hz, 100 Hz, 40 Hz  
INT-pin gives an interrupt by default when new data is available.  
2.3.2 Usage  
Acceleration data can be read from data output registers DOUTX, DOUTY and DOUTZ. See  
section 2.6 for INT-pin configuration details.  
2.4 Motion Detection Mode  
2.4.1 Description  
In MD mode the device works at 10 Hz sample rate and the fixed measurement range is 8 g. Signal  
is band pass filtered and fed to threshold level programmable digital comparator and a configurable  
trigger function. Filtered signal is also available at output registers.  
The device can be configured to switch automatically into the measurement mode with highest  
sampling rate (400Hz) after motion is detected. The measurement range used will be defined by  
G_RANGE bit.  
Nominal BPF's -3 dB high-pass frequency is 1.3 Hz and -3 dB low-pass frequency is 3.8 Hz. See  
Figure 3 below.  