CMA3000-D0X Series  
1.2.4 Supported features  
Supported features are listed in Table 1 below.  
Table 1. CMA3000-D0X devices’ summary.  
Features  
CMA3000-D01  
Supply voltage  
1.7 V – 3.6 V  
I/O voltage  
1.7 V – 3.6 V  
Measuring range (selectable)  
Resolution (2g /8g range)  
Sensitivity (2g /8g range)  
Motion detection  
Free fall detection  
Interface  
±2 g, ±8 g  
17 mg / 67 mg  
56 counts/g / 14 counts/g  
User enabled  
User enabled  
SPI max 500 kHz, I2C fast mode 400 kHz  
Internal  
Clock  
1.2.5 Operation modes  
1.2.5.1 Power Down  
In Power Down (PD) mode device's volatile register keep their contents and the current  
consumption is minimized. Power down mode is the default mode after start up.  
1.2.5.2 Measurement  
In Measurement mode (Meas) the sensor offers acceleration information via the digital SPI/I2C  
interface. Interrupt can be activated via INT-pin, when each xyz-acceleration sample is ready to be  
read.  
Measurement range and sample rate are user selectable according to Table 2. Measurement mode  
can be activated by detected motion.  
1.2.5.3 Motion Detection  
Motion Detection (MD) mode is intended to be used to save system level power consumption. In  
this mode, CMA3000-D0X activates the interrupt via the INT-pin when motion is detected. Motion  
sensitivity level can be configured via the SPI or I2C bus. Moreover, duration of the motion to be  
detected can be user defined. Once the interrupt has happened, the detected direction can be read  
out from the corresponding status register.  
Low sample rate (10 Hz) band-pass filtered acceleration information is available in MD mode. The  
device can be configured to switch automatically into the measurement mode with highest  
sampling rate after motion detection.  
1.2.5.4 Free-Fall Detection  
Free-Fall Detection (FFD) is intended to be used to save system resources. This feature activates  
the interrupt via the INT-pin when free-fall is detected. Acceleration information is available when  
the FFD is enabled.  
1.2.6 Interrupt  
The CMA3000 has a dedicated output pin (INT) to be used as the interrupt for the master  
controller. Interrupt conditions can be activated and deactivated via the SPI or I2C bus. Once the  
interrupt has happened, the interrupt source can be read out from the corresponding status  
register.  
VTI Technologies Oy  
www.vti.fi  
6/ 35  
Rev. 0.12  
Doc.Nr. 8281000.12  
 
 