KTPS65 Series
CEC/DoE Level VI
65 Watt
Universal Input, Desktop Adapter
INPUT SPECIFICATIONS
All specifications are typical at nominal input, full load.
INPUT SPECIFICATIONS
Input Voltage
Input Frequency
Input Current
Protection
AC 100 – 240VAC
50 – 60Hz
65W: 1.4A Max / 72W: 1.6A Max
Internal Primary Current Fuse,
Inrush Limiting
OUTPUT SPECIFICATIONS
FEATURES
Output Voltage
Efficiency
See Chart
DoE Level VI, Energy Star, ErP
Stage 2, NRCan & GEMS Level
VI Certified
CEC/DoE LEVEL VI
UNIVERSAL INPUT (AC100-240V)
OVER VOLTAGE PROTECTION
OVER CURRENT PROTECTION
SHORT CIRCUIT PROTECTION
ROHS COMPLIANT
Protection
Short Circuit Protection
Over Current Protection
(@180% Output A max)
Over Voltage Protection
1 - 2 % Vp-p (max)
ENVIRONMENTAL SPECIFICATIONS
Ripple
Operating Temperature
Storage Temperature
Cooling
0°C ~ +40°C
-20°C ~ +80°C
Convection
Hold-Up Time
Transient Response
Load Regulation
Leakage Current
10 mS (min)
0.5mS for 50% Load Change(typ)
± 5% (typ)
Operating Humidity
Storage Humidity
20 – 80% Rh
10 – 90% Rh
0.25mA @ 2 pin / 3.5mA @ 3 pin
GENERAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
MTBF(Calculated)
300,000 Calculated Hours at
25°C, by Telcordia SR-332
Case Dimension
L115 x W53 x H38(mm)
Dielectric Withstanding
Voltage
3,000 VAC Primary – Secondary
Input Configuration
IEC320-C14
(Optional C6)
EMI
Compliance to EN55022 Class B
DC Cord
18AWG
Conduction & Radiation
(Optional 16 AWG &
20AWG)
Harmonic Current
EMS Immunity
Compliance to EN61000-3-2,3
Output Connector
Weight
See Chart
310g (Ref)
Compliance to EN61000-4-
2,3,4,5,6,8,11
Safety Approvals
UL/cUL/CE/CB/GS/PSE/FCC
Kaga Electronics (USA) Inc. 780 Montague Expressway, Suite #403, San Jose, CA 95131
Phone: (408) 570-0955 | Fax: (408) 570-0186 | Toll Free: (888) 2-VOLGEN (888-286-5436)