KTPS50 Series
CEC/DoE Level VI
50 Watt
Universal Input, Desktop Adapter
INPUT SPECIFICATIONS
All specifications are typical at nominal input, full load.
INPUT SPECIFICATIONS
Input Voltage
Input Frequency
Input Current
Protection
AC 100 – 240VAC
50 – 60Hz
1.2A Max
Internal Primary Current Fuse,
Inrush Limiting
FEATURES
OUTPUT SPECIFICATIONS
CEC/DoE LEVEL VI
Output Voltage
Efficiency
See Chart
UNIVERSAL INPUT (AC100-240V)
OVER VOLTAGE PROTECTION
OVER CURRENT PROTECTION
SHORT CIRCUIT PROTECTION
ROHS COMPLIANT
DoE Level VI, Energy Star, ErP
Stage 2, NRCan & GEMS Level
VI Certified
Protection
Short Circuit Protection
Over Current Protection
Over Voltage Protection
1 - 2 % Vp-p (max)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
0°C ~ +40°C
-20°C ~ +80°C
Convection
Ripple
Hold-Up Time
Transient Response
Load Regulation
Leakage Current
10 mS (min)
0.5mS for 50% Load Change(typ)
± 5% (typ)
Operating Humidity
Storage Humidity
20 – 80% Rh
10 – 90% Rh
0.25mA @ 2 pin / 3.5mA @ 3 pin
MECHANICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Case Dimension
L115 x W53 x H38(mm)
L139 x W61 x H36(mm)
(KTPS50-0510DT-3P-VI)
MTBF(Calculated)
300,000 Calculated Hours at
25°C, by Telcordia SR-332
Dielectric Withstanding
Voltage
3,000 VAC Primary – Secondary
Input Configuration
DC Cord
IEC320-C14
(Optional C6)
EMI
Compliance to EN55022 Class B
18AWG
(Optional 16 AWG &
20AWG)
Conduction & Radiation
Harmonic Current
EMS Immunity
Compliance to EN61000-3-2,3
Compliance to EN61000-4-
2,3,4,5,6,8,11
Output Connector
Weight
See Chart
278g(Ref)
Safety Approvals
UL/cUL/CE/CB/GS/PSE/FCC
332g
(KTPS50-0510DT-3P-VI)
Kaga Electronics (USA) Inc. 780 Montague Expressway, Suite #403, San Jose, CA 95131
Phone: (408) 570-0955 | Fax: (408) 570-0186 | Toll Free: (888) 2-VOLGEN (888-286-5436)
www.volgen.com