200 V - 1,000 V Rectifiers
1N5614 1N5616
1N5618 1N5620
1N5622
1.5 A Forward Current
2000 ns Recovery Time
AXIAL LEADED
HERMETICALLY SEALED
MIL-PRF-19500/427
3
JAN JANTX JANTXV
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part
Working
Average
Rectified
Current
Reverse
Current
@ Vrwm
Forward
Voltage
1 Cycle Repetitive Reverse
Thermal
Junction
Cap.
@50VDC
@ 1kHZ
(Cj)
Number Reverse
Voltage
Surge
Current
tp=8.3ms
(Ifsm)
Surge
Current
Recovery
Time
(3)
Impedance
u
J-L
(Vrwm)
(Io)
(Ir)
(Vf)
(Ifrm)
25°C
(Trr)
55°C(1) 100°C(2) 25°C 100°C
25°C
25°C
25°C
ns
L=.125 L=.375 L=.500
25°C
pF
Volts
Amps
Amps
µA
µA
Volts Amps
Amps
Amps
°C/W
°C/W
°C/W
200
400
1.50
1.50
0.75
0.75
0.5
0.5
25
25
1.3 3.00
1.3 3.00
30
30
10
10
2000
2000
18
18
38
38
45
45
16
16
1N5614
1N5616
600
800
1.50
1.50
0.75
0.75
0.5
0.5
25
25
1.3 3.00
1.3 3.00
30
30
10
10
2000
2000
18
18
38
38
45
45
16
16
1N5618
1N5620
1N5622
1000
1.50
0.75
0.5
25
1.3 3.00
30
10
2000
18
38
45
16
(1)TL=55°C L=0.375" (2)TL=100°C L=0.375" (3)If=0.5A, Ir=1.0A, Irr=0.25A • Op.Temp.= -65°C to +175°C Stg.Temp.= -65°C to +200°C
.110(2.8)
.065(1.65)
.185(4.7)
MAX.
1.30(33.02)
.90(22.86)
.033(8.38)
.026(.66)
Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice.
VOLTAGE MULTIPLIERS INC.
8711 W. Roosevelt Ave.
Visalia, CA 93291
TEL
FAX
559-651-1402
559-651-0740
www.voltagemultipliers.com