ILCT6/MCT6
Vishay Semiconductors
Optocoupler, Phototransistor Output,
Dual Channel
ABSOLUTE MAXIMUM RATINGS
PARAMETER
INPUT
Rated forward current, DC
Peak forward current, DC
Power dissipation
Derate linearly from 25 °C
OUTPUT
Collector current
Collector emitter breakdown voltage
Power dissipation
Derate linearly from 25 °C
COUPLER
Isolation test voltage
Isolation resistance
Creepage distance
Clearance distance
Total package dissipation
Derate linearly from 25 °C
Storage temperature
Operating temperature
Lead soldering time at 260 °C
P
tot
T
stg
T
amb
V
IO
= 500 V, T
amb
= 25 °C
V
IO
= 500 V, T
amb
= 100 °C
1.0 µs pulse, 300 pps
I
FM
P
diss
60
3.0
100
1.3
30
30
150
2.0
5300
≥
10
12
≥
10
11
≥
7.0
≥
7.0
400
5.33
- 55 to + 150
- 55 to + 100
10
mA
A
mW
mW/°C
mA
V
mW
mW/°C
V
RMS
Ω
Ω
mm
mm
mW
mW/°C
°C
°C
s
TEST CONDITION
SYMBOL
VALUE
UNIT
I
C
BV
CEO
P
diss
V
ISO
R
IO
R
IO
Note
T
amb
= 25 °C, unless otherwise specified.
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied
at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum ratings for
extended periods of the time can adversely affect reliability.
ELECTRICAL CHARACTERISTICS
PARAMETER
INPUT
Forward voltage
Reverse current
Junction capacitance
OUTPUT
Collector emitter breakdown voltage
Emitter collector breakdown voltage
Collector emitter leakage current
Collector emitter capacitance
COUPLER
Saturation voltage, collector emitter
Capacitance (input to output)
Capacitance between channels
Bandwidth
I
C
= 2.0 mA, I
F
= 16 mA
f = 1.0 MHz
f = 1.0 MHz
I
C
= 2.0 mA, V
CC
= 10 V,
R
L
= 100
Ω
V
CEsat
C
IO
0.5
0.4
150
0.40
V
pF
pF
kHz
I
C
= 1.0 µA, I
E
= 10 µA
I
C
= 10
μA,
I
E
= 10 µA
V
CE
= 10 V
V
CE
= 0 V
BV
CEO
BV
ECO
I
CEO
C
CE
30
7.0
65
10
1.0
8.0
100
V
V
nA
pF
I
F
= 20 mA
V
R
= 3.0 V
V
F
= 0 V
V
F
I
R
C
j
1.25
0.1
25
1.50
10
V
µA
pF
TEST CONDITION
SYMBOL
MIN.
TYP.
MAX.
UNIT
Note
T
amb
= 25 °C, unless otherwise specified.
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are the result of engineering
evaluation. Typical values are for information only and are not part of the testing requirements.
www.vishay.com
2
For technical questions, contact: optocoupler.answers@vishay.com
Document Number: 83645
Rev. 1.5, 20-Dec-07