型号: MCT6
PDF下载: 下载PDF文件 查看货源
内容描述: 光电耦合器,光电晶体管输出,双通道 [Optocoupler, Phototransistor Output, Dual Channel]
分类和应用: 晶体光电晶体管光电晶体管
文件页数/大小: 7 页 / 130 K
品牌: VISHAY [ VISHAY TELEFUNKEN ]
 浏览型号MCT6的Datasheet PDF文件第2页浏览型号MCT6的Datasheet PDF文件第3页浏览型号MCT6的Datasheet PDF文件第4页浏览型号MCT6的Datasheet PDF文件第5页浏览型号MCT6的Datasheet PDF文件第6页浏览型号MCT6的Datasheet PDF文件第7页  
ILCT6/ MCT6
Vishay Semiconductors
Optocoupler, Phototransistor Output, Dual Channel
Features
Current Transfer Ratio, 50 % Typical
Leakage Current, 1.0 nA Typical
Two Isolated Channels Per Package
Lead-free component
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
A
C
C
A
1
2
3
4
8 E
7 C
6 C
5 E
Agency Approvals
• UL1577, File No. E52744 System Code H or J,
Double Protection
• DIN EN 60747-5-2 (VDE0884)
DIN EN 60747-5-5 pending
Available with Option 1
• CSA 93751
• BSI IEC60950 IEC60065
i179016
e3
Pb
Pb-free
can also be used to replace relays and transformers
in many digital interface applications, as well as ana-
log applications such as CRT modulation.
Order Information
Part
ILCT6
MCT6
ILCT6-X007
ILCT6-X009
MCT6-X007
MCT6-X009
Remarks
CTR
20 %, DIP-8
CTR
20 %, DIP-8
CTR
20 %, SMD-8 (option 7)
CTR
20 %, SMD-8 (option 9)
CTR
20 %, SMD-8 (option 7)
CTR
20 %, SMD-8 (option 9)
Description
The ILCT6/ MCT6 is a two channel optocoupler for
high density applications. Each channel consists of
an optically coupled pair with a Gallium Arsenide
infrared LED and a silicon NPN phototransistor. Sig-
nal information, including a DC level, can be transmit-
ted by the device while maintaining a high degree of
electrical isolation between input and output.
The ILCT6/ MCT6 is especially designed for driving
medium-speed logic, where it may be used to elimi-
nate troublesome ground loop and noise problems. It
For additional information on the available options refer to
Option Information.
Absolute Maximum Ratings
T
amb
= 25 °C, unless otherwise specified
Stresses in excess of the absolute Maximum Ratings can cause permanent damage to the device. Functional operation of the device is
not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute
Maximum Rating for extended periods of the time can adversely affect reliability.
Input
Parameter
Rated forward current, DC
Peak forward current, DC
Power dissipation
Derate linearly from 25 °C
1.0
µs
pulse, 300 pps
I
FM
P
diss
Test condition
Symbol
Value
60
3.0
100
1.3
Unit
mA
A
mW
mW/°C
Document Number 83645
Rev. 1.4, 26-Oct-04
www.vishay.com
1