DG408/409
Vishay Siliconix
SPECIFICATIONS
a
FOR SINGLE SUPPLY
Test Conditions
Unless Otherwise Specified
V+ = 12 V, V- = 0 V
Parameter
Analog Switch
Drain-Source
On-Resistance
e,f
Dynamic Characteristics
Switching Time of Multiplexer
e
Enable Turn-On
Time
e
Enable Turn-Off Time
e
Charge Injection
e
Symbol
V
AL
= 0.8 V, V
AH
= 2.4 V
f
Temp
b
Typ
c
A Suffix
- 55 to 125 °C
Min
d
Max
d
D Suffix
- 40 to 85 °C
Min
d
Max
d
Unit
Ω
r
DS(on)
V
D
= 3 V, 10 V, I
S
= - 1 mA
Room
90
t
TRANS
t
ON(EN)
t
OFF(EN)
Q
V
S1
= 8 V, V
S8
= 0 V, V
IN
= 2.4 V
V
INH
= 2.4 V, V
INL
= 0 V
V
S1
= 5 V
C
L
= 1 nF, V
S
= 6 V, R
S
= 0
Room
Room
Room
Room
180
180
120
5
pC
ns
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
g.
Δr
DS(on)
= r
DS(on)
MAX - r
DS(on)
MIN.
h. Worst case isolation occurs on Channel 4 due to proximity to the drain pin.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
4
Document Number: 70062
S-71155–Rev. G, 11-Jun-07