DG201B/202B
Vishay Siliconix
SPECIFICATIONS FOR SINGLE SUPPLY
a
Test Conditions
Unless Specified
Parameter
Analog Switch
Analog Signal Range
e
Drain-Source
On-Resistance
V
ANALOG
r
DS(on)
V
D
= 3 V, 8 V, I
S
= 1 mA
Full
Room
Full
90
A Suffix
–55 to 125_C
D Suffix
–40 to 85_C
Symbol
V+ = 12 V, V– = 0 V
V
IN
= 2.4 V, 0.8 V
f
Temp
b
Typ
c
Min
d
Max
d
Min
d
Max
d
Unit
0
12
160
200
0
12
160
200
V
W
Dynamic Characteristics
Turn-On Time
Turn-Off Time
Charge Injection
t
ON
t
OFF
Q
V
S
= 8 V
See Switching Time T t Circuit
S S it hi Ti
Test Ci it
C
L
= 1 nF, V
gen
= 6 V, R
gen
= 0
W
Room
Room
Room
120
60
4
300
200
300
200
ns
pC
Power Supply
Positive Supply Current
Negative Supply Current
Power Supply Range for
Continuous Operation
I+
V
IN
= 0 or 5 V
I–
V
OP
Room
Full
Room
Full
Full
100
-1
-5
)
4.5
)
25
50
100
-1
-5
)
4.5
)
25
50
mA
V
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f.
V
IN
= input voltage to perform proper function.
www.vishay.com
S
FaxBack 408-970-5600
4-4
Document Number: 70037
S-52433—Rev. G, 06-Sep-99