V23990-P848-A58/A59/C58/C59-PM
preliminary datasheet
flowPIM 2 3rd
1200V/4A
Output Inverter Application
Figure 9
Inverter
Figure 10
Inverter
Typical available peak output power as a function of
Typical efficiency as a function of output power
Pout=f(Th)
efficiency=f(Pout)
heatsink temperature
3,0
100,0
2kHz
99,0
98,0
97,0
96,0
95,0
94,0
93,0
92,0
91,0
90,0
16kHz
2,5
2,0
1,5
1,0
0,5
0,0
2kHz
16kHz
60
65
70
75
80
85
90
95
100
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
Pout (kW)
9,0
Th
(
o C)
At
At
Tj =
Tj =
150
°C
V
150
°C
V
DC link = 600
DC link = 600
Mi =
1
Mi =
1
cosfi =
0,80
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw from 2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
peak / Pnom=f(Pnom,fsw
Typical available overload factor as a function of
motor power and switching frequency
P
)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
0,50 / 0,37
599
0,75 / 0,55
399
1,00 / 0,74
300
1,50 / 1,10
200
2,00 / 1,47
150
3,00 / 2,21
0
0
0
0
0
1
599
399
300
200
150
2
599
399
300
200
150
4
599
399
300
200
150
8
599
399
300
200
150
16
At
Tj =
150
°C
V
DC link = 600
Mi =
1
cosfi =
0,8
fsw from 1 kHz to 16kHz in steps of factor 2
Th = 90 °C
Motor eff = 0,85
copyright Vincotech
3
Revision: 1