V23990-P840-A58/A59/C58/C59-PM
preliminary datasheet
Output Inverter Application
Figure 5
Phase
Figure 6
Phase
Typical available 50Hz output current
as a function Mi*cosfi
Typical available 50Hz output current
as a function of switching frequency
Iout = f(Mi*cosfi)
Iout = f(fsw)
25
20
15
10
5
25
Th=60°C
Th=60°C
20
15
Th=100°C
Th=100°C
10
5
0
0
-1,0
-0,8
-0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,8
Mi*cosfi
1,0
1
10
100
fsw (kHz)
Tj =
DC link = 600
fsw =
Tj =
125
°C
125
°C
V
V
DC link = 600
Mi*cosfi = 0,8
8
kHz
Th from 60 °C to 100 °C in steps of 5 °C
Th from 60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
out = f(fsw, Mi*cosfi)
Figure 8
Phase
Typical available 50Hz output current as a function of
Mi*cosfi and switching frequency
Typical available 0Hz output current as a function
of switching frequency
I
Ioutpeak = f(fsw)
25
-1,00
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
1,00
Iout (A)
20
Th=60°C
20,0-22,0
18,0-20,0
16,0-18,0
14,0-16,0
12,0-14,0
10,0-12,0
8,0-10,0
6,0-8,0
15
Th=100°C
10
5
0
1
1
2
4
8
16
32
10
100
fsw
fsw (kHz)
Tj =
DC link = 600
Th =
Tj =
DC link = 600
125
°C
125
°C
V
V
°C
80
Th from 60 °C to 100 °C in steps of 5 °C
copyright Vincotech
2
Revision: 2