V23990-P765-A-PM
prel datasheet
flowPIM 2 3rd
600V/100A
Output Inverter Application
Figure 9
Inverter
Figure 10
Typical efficiency as a function of output power
Inverter
Typical available peak output power as a function of
Pout=f(Th)
efficiency=f(Pout)
heatsink temperature
40,0
100,0
2kHz
35,0
30,0
25,0
20,0
15,0
10,0
5,0
99,0
98,0
97,0
96,0
95,0
94,0
2kHz
16kHz
16kHz
0,0
60
65
70
75
80
85
90
95
Th
100
0,0
5,0
10,0
15,0
20,0
25,0
30,0
35,0
40,0
Pout (kW)
45,0
(
o C)
At
At
Tj =
Tj =
150
°C
V
150
°C
V
DC link = 320
DC link = 320
Mi =
1
Mi =
1
cosfi =
0,80
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw from 2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
peak / Pnom=f(Pnom,fsw
Typical available overload factor as a function of
motor power and switching frequency
P
)
450
400
350
300
250
200
150
100
Motor nominal power (HP/kW)
10,00 / 7,36
379
15,00 / 11,03
20,00 / 14,71
25,00 / 18,39 30,00 / 22,07
40,00 / 29,42
253
249
241
226
198
190
187
181
169
149
152
149
144
135
119
126
124
120
113
0
0
0
0
0
0
1
373
2
361
4
338
8
297
16
At
Tj =
150
°C
V
DC link = 320
Mi =
1
cosfi =
0,8
fsw from 1 kHz to 16 kHz in 2 steps
Th = 80 °C
Motor eff = 0,85
copyright Vincotech
3
Revision: 1