20-1B06IPB004RC-P952A40
20-PB06IPB004RC-P952A40Y
datasheet
Output Inverter
Figure 17
Output inverter IGBT
Safe operating area as a function
of collector-emitter voltage
I C = f(V CE
)
102
101
100
10-1
10-2
100
101
102
103
VCE (V)
At
T jmax
T j
≤
ºC
V
UCC
=
15
Figure 18
Reverse bias safe operating area
IGBT
I C = f(V CE
)
10
IC MAX
8
6
4
2
0
0
100
200
300
400
500
600
700
VCE (V)
At
T j
=
T jmaxꢀ25
ºC
copyright Vincotech
14