Electrical Characteristics, continued
MODULE CONTROL SPECIFICATIONS
Parameter
AC Bus OK (B OK)
On-state resistance (low)
On-state current (low)
Off-state voltage
On-state threshold
Off-state threshold
Module Enable (EN)
On-state resistance (low)
On-state current (low)
Off-state voltage
On-state threshold
Off-state threshold
Over voltage shutdown
AC Bus OK - module enable, differential error*
Min
Typ
Max
15
-50
Unit
Ω
mA
Vdc
Vdc
Vdc
Notes
To negative output - bus normal
Bus normal
Bus abnormal, 27K internal pull up to 15Vdc (Fig. 10)
Output bus voltage
Output bus voltage
14.8
235
200
15.0
240
205
15.2
245
210
15
50
14.8
235
200
380
15
15.0
240
205
390
17
15.2
245
210
400
20
Ω
mA
Vdc
Vdc
Vdc
Vdc
Vdc
To negative output - converters are disabled
150K internal pull up to 15Vdc (Fig. 9)
Output bus voltage
Output bus voltage
AC Bus OK and module enable thresholds track
* Tracking error between BUS OK and Enable thresholds
MODULE GENERAL SPECIFICATIONS
Parameter
MTBF
Baseplate material
Cover
Pin material
Weight
Size
Min
Typ
>1,000,000
Max
Unit
hours
Notes
25˚C, ground benign
Aluminum
Polyetherimide
Copper, tin/lead solder dipped
2.1 (60)
2.28 x 1.45 x 0.5
(57,9 x 36,8 x 12,7)
ounces (grams)
inches
(mm)
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
ARM, Autoranging Rectifier Module
Rev. 2.4
Page 3 of 12
Set your site on VICOR at www.vicorpower.com