MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
PRIMARY SIDE
(PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
SECONDARY SIDE
(SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
Vdc
Ω
µF
Vdc
With open trim; referenced to –Sense. See Fig. 6
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
Vdc
mA
Vdc
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20 ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 2 and 4
See Fig. 2
PR load >30 Ω, < 30 pF
PC current = 1.0 mA
PC voltage = 5.5 V
Must be able to sink ≥4 mA. See Fig. 1
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation voltage
in to out
in to base
out to base
Isolation resistance (in to out)
Weight
Temperature limiting
3.5
(99.6)
100
3000
1500
500
10
3.9
(110.6)
115
cURus, TÜV, CE
4.3
(121.6)
Min
Typ
Max
0.5
Unit
Vdc
Vrms
Vrms
Vrms
MΩ
ounces
(grams)
°C
See Figs. 2 and 4
UL60950-1, CSA0950-1, EN60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25 V per leg (senses must be closed)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
Note:
Specifications are subject to change without notice.
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
48V Mini Family
Rev. 7.4
Page 3 of 11
Set your site on VICOR at vicorpower.com