MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
8 Vout, 100 W (e.g.V300C8C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.2
9.36
Typ
82.3
220
9.7
3.8
±0.02
14.4
14.4
Max
275
10.1
4.4
±0.2
12.5
16.9
16.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0
12.7
8.75
12 Vout, 150 W (e.g. V300C12C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.3
13.7
Typ
85.3
170
14.3
5
±0.02
14.4
14.4
Max
213
14.9
7.5
±0.2
12.5
16.3
16.3
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
12.7
8.75
12 Vout, 75 W (e.g. V300C12C75BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
13.7
Typ
85
200
14.3
4
±0.02
7.19
7.19
Max
250
14.9
5.3
±0.2
6.25
8.44
8.44
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
6.37
4.37
15 Vout, 150 W (e.g. V300C15C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.5
17.1
Typ
86.5
150
17.8
7
±0.02
11.5
11.5
Max
188
18.5
10.5
±0.2
10
13
13
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage < 250 mV
0
10.2
3
15 Vout, 75 W (e.g. V300C15C75BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.2
17.1
Typ
85.2
150
17.8
3
±0.02
5.75
5.75
Max
188
18.5
5
±0.2
5
6.75
6.75
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
0
5.1
3.5
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
300V Micro Family
Rev. 8.7
Page 5 of 13
Set your site on VICOR at vicorpower.com