CONTROL FUNCTIONS - PC PIN  
Module Enable/Disable  
Module Alarm  
The module may be disabled by pulling PC below 2.3V with  
respect to the –Input. This may be done with an open collector  
transistor, relay, or optocoupler. Multiple converters may be  
disabled with a single transistor or relay either directly or via  
“OR’ing” diodes. See Figure 1.  
The module contains “watchdog” circuitry which monitors  
input voltage, operating temperature and internal operating  
parameters. In the event that any of these parameters are  
outside of their allowable operating range, the module will shut  
down and PC will go low. PC will periodically go high and the  
module will check to see if the fault (as an example,  
overtemperature) has cleared. If the fault has not been cleared,  
PC will go low again and the cycle will restart. The SC pin will  
go low in the event of a fault and return to its normal state after  
the fault has been cleared. See Figures 2 and 4.  
Primary Auxiliary Supply  
At 5.7V, PC can source up to 1.5mA. In the example shown in  
Figure 3, PC powers a module enabled LED.  
Input Undervoltage  
Input Overvoltage  
+Out  
+In  
PC  
+In  
PC  
Overtemperature  
+Out  
Auto  
Restart  
Module Faults  
SW1  
+S  
SC  
–S  
+S  
SC  
–S  
2-20ms typ.  
50  
f (V )  
IN  
SW1, 2, & 3  
shown in  
"Fault" position  
1K  
SW2  
SW3  
PR  
–In  
Disable  
PR  
–In  
5.7Vdc  
(0-3mA)  
1.23  
Vdc  
–Out  
–Out  
6K  
Disable = PC <2.3V  
Figure 1—Module enable/disable.  
Figure 2—PC/SC module alarm logic.  
+In  
PC  
+Out  
Fault  
PC  
40µs typ.  
5.7V  
+S  
SC  
–S  
4k  
"Module  
PR  
–In  
Enabled"  
1.23V  
2-20ms typ.  
SC  
–Out  
Figure 3—LED on-state indicator.  
Figure 4—PC/SC module alarm timing.  
Optocoupler  
+In  
PC  
+In  
PC  
+Out  
+Out  
+S  
SC  
–S  
+S  
SC  
–S  
Alarm  
4kW  
PR  
–In  
PR  
–In  
1.00V  
–Out  
–Out  
Figure 5—Isolated on-state indicator.  
Figure 6—Secondary side on-state indicator.  