欢迎访问ic37.com |
会员登录 免费注册
发布采购

V24C5H100A 参数 Datasheet PDF下载

V24C5H100A图片预览
型号: V24C5H100A
PDF下载: 下载PDF文件 查看货源
内容描述: 24VIN / 28Vout / 100Watts DC -DC转换器模块 [24Vin / 28Vout / 100Watts DC-DC Converter Module]
分类和应用: 转换器电源电路光电二极管
文件页数/大小: 8 页 / 524 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号V24C5H100A的Datasheet PDF文件第1页浏览型号V24C5H100A的Datasheet PDF文件第2页浏览型号V24C5H100A的Datasheet PDF文件第3页浏览型号V24C5H100A的Datasheet PDF文件第4页浏览型号V24C5H100A的Datasheet PDF文件第5页浏览型号V24C5H100A的Datasheet PDF文件第7页浏览型号V24C5H100A的Datasheet PDF文件第8页  
CONTROL FUNCTIONS - PR PIN
Compatible interface architectures include the following:
DC coupled single-wire interface.
All PR pins are directly con-
nected to one another. This interface supports current sharing
but is not fault tolerant. Minus In pins must be tied to the same
electric potential. See Figure 9.
AC coupled single-wire interface.
All PR pins are connected to
a single communication bus through .001µF (500V) capacitors.
This interface supports current sharing and is fault tolerant
except for the communication bus. See Figure 10.
Parallel Operation
The PR pin supports paralleling for increased power with N+1
(N+M) redundancy and phased array capability. Modules of
the same input voltage, output voltage, and power level will
current share if all PR pins are suitably interfaced.
+In
PC
PR
–In
+Out
+In
+Out
Module 1
SC
.001µF
PC
PR
Module 1
SC
–Out
–In
–Out
+In
PC
PR
–In
+Out
+In
+Out
Module 2
(up to 12)
SC
.001µF
PC
PR
Module 2
(up to 12)
SC
–Out
–In
–Out
Ground plane
Ground plane
Figure 9—DC
coupled single-wire interface.
Figure 10—AC
coupled single-wire interface.
+Out
SC
–Out
Plane
+Out
SC
–Out
L
O
A
D
• The +Out and –Out
power buses should be
designed to minimize
and balance parasitic
impedance from each
module output to the
load.
• At the discretion of the
power system designer,
a subset of all modules
within an array may be
configured as slaves by
shorting SC to –Out.
+Out
Volt Drop
Compensator
V+ 7
R3
3
1
8
2
R2
• OR’ing diodes may be inserted
in series with the +Out pin of
each module to provide output
fault tolerance. As an example,
the circuit shown may be used
to compensate for the voltage
drop of the diode.
R1
Load
SC
6
LM10
V- 4
C1
+Out
SC
–Out
Ground
Plane
–Out
• This module is designed for point
of load regulation, where remote
sensing is not required. Active
voltage drop
compensator, as shown here,
may be used in applications with
significant distribution
losses. Details of this circuit are
available in the design guide.
Figure 11—N+1
module array output connections.
Figure 12—OR’ing
diodes connections and voltage drop compensation.
Vicor Corporation
Tel: 800-735-6200 Fax: 978-475-6715
Data Sheet: V24C28C100A DC-DC Converter Date: 11-00 Rev. 2
Page 6 of 8
Set your site on VICOR at www.vicr.com