 浏览型号DCM420P120T400A40的Datasheet PDF文件第2页浏览型号DCM420P120T400A40的Datasheet PDF文件第3页浏览型号DCM420P120T400A40的Datasheet PDF文件第4页浏览型号DCM420P120T400A40的Datasheet PDF文件第5页浏览型号DCM420P120T400A40的Datasheet PDF文件第7页浏览型号DCM420P120T400A40的Datasheet PDF文件第8页浏览型号DCM420P120T400A40的Datasheet PDF文件第9页浏览型号DCM420P120T400A40的Datasheet PDF文件第10页  
DCM300P120x400A40  
Electrical Specifications (cont.)  
Specifications apply over all line, trim and load conditions, internal temperature TINT = 25ºC, unless otherwise noted. Boldface specifications apply over the  
temperature range of -40°C < TINT < 125°C for T grade and -55°C < TINT < 125°C for M grade.  
Attribute  
Symbol  
Conditions / Notes  
Min  
10  
Typ  
Max  
Unit  
Power Output Specifications (Cont.)  
At 10 kHz, excludes component tolerances  
See state diagram  
Output capacitance, ESR (ext.)  
Initialization delay  
RCOUT-EXT  
tINIT  
mΩ  
ms  
25  
40  
From rising edge EN, with VIN pre-applied. See timing  
diagram  
Output turn-on delay  
Output turn-off delay  
tON  
200  
µs  
µs  
tOFF  
From falling edge EN. See timing diagram  
600  
100  
At full rated resistive load. Typ spec is 1-up with min  
COUT-EXT. Max spec is for arrays with max COUT-EXT  
During startup, VOUT must achieve this threshold before  
Soft start ramp time  
tSS  
36  
ms  
VOUT threshold for max  
rated load current  
VOUT-FL-THRESH  
IOUT-START  
VOUT-MONOTONIC  
6.0  
V
A
output can support full rated current  
Max load current at startup while VOUT  
IOUT at startup  
3.33  
is below VOUT-FL_THRESH  
Monotonic soft-start threshold  
voltage  
Output voltage rise becomes monotonic with 10% of  
preload once it crosses VOUT-MONOTONIC  
6.0  
2
V
This refers to the minimum time a module needs to be  
in the disabled state before it will attempt to start via EN  
Minimum required disabled duration  
tOFF-MIN  
ms  
This refers to the minimum time a module needs to be in  
tOFF-MONOTONIC the disabled state before it is guaranteed to exhibit  
monotonic soft-start and have predictable startup timing  
Minimum required disabled duration  
for predictable restart  
100  
ms  
Voltage deviation (transient)  
Settling time  
%VOUT-TRANS  
<10  
8.0  
%
Minimum COUT_EXT (10 90% load step), excluding  
load line.  
tSETTLE  
ms  
Powertrain Protections  
Input Voltage Initialization threshold  
Input Voltage Reset threshold  
VIN-INIT  
VIN-RESET  
VIN-UVLO-  
VIN-UVLO+  
VIN-OVLO+  
VIN-OVLO-  
Threshold to start tINIT delay  
75  
V
V
V
V
V
V
Latching faults will clear once VIN falls below VIN-RESET  
50  
Input undervoltage recovery threshold  
Input undervoltage lockout threshold  
Input overvoltage lockout threshold  
Input overvoltage recovery threshold  
125  
170  
178  
455  
See Timing diagram  
See Timing diagram  
423  
Output overvoltage threshold  
Output overvoltage threshold  
VOUT-OVP  
From 25% to 100% load. Latched shutdown  
15.8  
V
V
VOUT-OVP-LL  
From 0% to 25% load. Latched shutdown  
16.2  
125  
Minimum current limited VOUT  
Overtemperature threshold (internal)  
Power limit  
VOUT-UVP  
TINT-OTP  
PLIM  
Over all operating steady-state line and trim conditions  
5
V
°C  
W
650  
VIN overvoltage to cessation of  
powertrain switching  
tOVLO-SW  
Independent of fault logic  
For fault logic only  
1.5  
µs  
VIN overvoltage response time  
VIN undervoltage response time  
Short circuit response time  
tOVLO  
tUVLO  
tSC  
200  
100  
200  
µs  
ms  
µs  
Powertrain on, operational state  
See Timing diagram  
Short circuit, or temperature fault  
recovery time  
tFAULT  
1
s
DCMDC-DC Converter  
Rev 1.2  
vicorpower.com  
800 927.9474  
Page 6 of 25  
07/2015