欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414BH0E5035T10 参数 Datasheet PDF下载

BCM4414BH0E5035T10图片预览
型号: BCM4414BH0E5035T10
PDF下载: 下载PDF文件 查看货源
内容描述: [Isolated Fixed-Ratio DC-DC Converter]
分类和应用:
文件页数/大小: 43 页 / 1351 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第4页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第5页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第6页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第7页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第9页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第10页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第11页浏览型号BCM4414BH0E5035T10的Datasheet PDF文件第12页  
BCM4414xH0E5035yzz  
Electrical Specifications (Cont.)  
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of  
–40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.  
Attribute  
Symbol  
Conditions / Notes  
Min  
Typ  
Max  
Unit  
Powertrain Supervisory Limits Specification – Forward Direction Operation (High-Voltage Side to Low-Voltage Side)  
• These supervisory limits are set in the internal controller and can be reconfigured or disabled through PMBus™.  
• When disabled, the powertrain protections presented in the previous table will intervene during fault events.  
HI-Side Overvoltage  
Lockout Threshold  
VHI_OVLO+  
VHI_OVLO–  
VHI_OVLO_HYST  
tHI_OVLO  
830  
800  
860  
830  
20  
880  
850  
V
V
HI-Side Overvoltage  
Recovery Threshold  
HI-Side Overvoltage  
Lockout Hysteresis  
V
HI-Side Overvoltage  
Lockout Response Time  
100  
450  
480  
20  
µs  
V
HI-Side Undervoltage  
Lockout Threshold  
VHI_UVLO–  
430  
470  
470  
499  
HI-Side Undervoltage  
Recovery Threshold  
VHI_UVLO+  
VHI_UVLO_HYST  
tHI_UVLO  
V
HI-Side Undervoltage  
Lockout Hysteresis  
V
HI-Side Undervoltage  
Lockout Response Time  
100  
µs  
From VHI_DC = VHI_UVLO+ to powertrain active  
HI-Side Undervoltage Start Up Delay tHI_UVLO+_DELAY (i.e., one-time start up delay from application of  
VHI_DC to VLO_DC  
50  
ms  
)
LO-Side Overcurrent  
Trip Threshold  
ILO_OUT_OCP  
tLO_OUT_OCP  
tOTP+  
37  
50  
2
60  
A
LO-Side Overcurrent  
Response Time Constant  
Effective internal RC filter  
Internal  
ms  
°C  
°C  
Overtemperature  
Shut-Down Threshold  
125  
Overtemperature  
Recovery Threshold  
tOTP–  
Internal  
105  
110  
115  
T-Grade  
–45  
–55  
Undertemperature  
Shut-Down Threshold (Internal)  
tUTP  
°C  
s
M-Grade  
Start up into a persistent fault condition. Non-latching  
fault detection given VHI_DC > VHI_UVLO+  
Undertemperature Restart Time  
tUTP_RESTART  
3
BCM® in a VIA™ Package  
Page 8 of 43  
Rev 1.0  
04/2019