 浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第30页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第31页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第32页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第33页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第35页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第36页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第37页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第38页  
BCM4414xH0E5035yzz  
READ_VIN Command (88h)  
READ_POUT Command (96h)  
If PAGE data byte is equal to (01h), command will return the BCM’s  
LO-side power in the following format:  
If PAGE data byte is equal to (01h), command will return the BCM’s  
HI-side voltage in the following format:  
PLO_ACTUAL = PLO_REPORTED (W)  
VHI_ACTUAL = VHI_REPORTED • 10-1(V)  
If PAGE data byte is equal to (00h), command will also return the  
BCM’s LO-side power.  
READ_IIN Command (89h)  
MFR_VIN_MIN Command (A0h),  
MFR_VIN_MAX Command (A1h),  
MFR_VOUT_MIN Command (A4h),  
MFR_VOUT_MAX Command (A5h),  
MFR_IOUT_MAX Command (A6h),  
MFR_POUT_MAX Command (A7h)  
If PAGE data byte is equal to (01h), command will return the BCM’s  
IHI_ACTUAL = IHI_REPORTED • 10-3(A)  
HI-side current in the following format:  
If PAGE data byte is equal (00h), command will also return the  
BCM’s HI-side current.  
These values are set by the factory and indicate the device  
HI-side/LO-side voltage and LO-side current range and LO-side  
power capacity.  
READ_VOUT Command (8Bh)  
If the PAGE data byte is equal to (00h – 01h),commands report  
the rated BCM HI-side voltage minimum and maximum in Volts,  
LO-side voltage minimum and maximum in Volts, LO-side current  
maximum in Amperes and LO-side power maximum in Watts.  
VLO_ACTUAL = VLO_REPORTED • 10-1(V)  
If PAGE data byte is equal to (01h), command will return the BCM’s  
LO-side voltage in the following format:  
READ_IOUT Command (8Ch)  
ILO_ACTUAL = ILO_REPORTED • 10-2(A)  
If PAGE data byte is equal to (01h), command will return the BCM’s  
LO-side current in the following format:  
If PAGE data byte is equal (00h), command will also return the  
BCM’s LO-side current.  
READ_TEMPERATURE_1 Command (8Dh)  
TACTUAL = TREPORTED (°C)  
If PAGE data byte is equal to (01h), command will return the BCM’s  
temperature in the following format:  
If PAGE data byte is equal (00h), command will also return the  
BCM’s temperature  
BCM® in a VIA™ Package  