BCM4414xH0E5035yzz
READ_VIN Command (88h)
READ_POUT Command (96h)
If PAGE data byte is equal to (01h), command will return the BCM’s
LO-side power in the following format:
If PAGE data byte is equal to (01h), command will return the BCM’s
HI-side voltage in the following format:
PLO_ACTUAL = PLO_REPORTED (W)
VHI_ACTUAL = VHI_REPORTED • 10-1(V)
If PAGE data byte is equal to (00h), command will also return the
BCM’s LO-side power.
READ_IIN Command (89h)
MFR_VIN_MIN Command (A0h),
MFR_VIN_MAX Command (A1h),
MFR_VOUT_MIN Command (A4h),
MFR_VOUT_MAX Command (A5h),
MFR_IOUT_MAX Command (A6h),
MFR_POUT_MAX Command (A7h)
If PAGE data byte is equal to (01h), command will return the BCM’s
IHI_ACTUAL = IHI_REPORTED • 10-3(A)
HI-side current in the following format:
If PAGE data byte is equal (00h), command will also return the
BCM’s HI-side current.
These values are set by the factory and indicate the device
HI-side/LO-side voltage and LO-side current range and LO-side
power capacity.
READ_VOUT Command (8Bh)
If the PAGE data byte is equal to (00h – 01h),commands report
the rated BCM HI-side voltage minimum and maximum in Volts,
LO-side voltage minimum and maximum in Volts, LO-side current
maximum in Amperes and LO-side power maximum in Watts.
VLO_ACTUAL = VLO_REPORTED • 10-1(V)
If PAGE data byte is equal to (01h), command will return the BCM’s
LO-side voltage in the following format:
READ_IOUT Command (8Ch)
ILO_ACTUAL = ILO_REPORTED • 10-2(A)
If PAGE data byte is equal to (01h), command will return the BCM’s
LO-side current in the following format:
If PAGE data byte is equal (00h), command will also return the
BCM’s LO-side current.
READ_TEMPERATURE_1 Command (8Dh)
TACTUAL = TREPORTED (°C)
If PAGE data byte is equal to (01h), command will return the BCM’s
temperature in the following format:
If PAGE data byte is equal (00h), command will also return the
BCM’s temperature
BCM® in a VIA™ Package
Page 34 of 43
Rev 1.0