欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414BH0E5035M06 参数 Datasheet PDF下载

BCM4414BH0E5035M06图片预览
型号: BCM4414BH0E5035M06
PDF下载: 下载PDF文件 查看货源
内容描述: [Isolated Fixed-Ratio DC-DC Converter]
分类和应用:
文件页数/大小: 43 页 / 1351 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第18页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第19页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第20页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第21页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第23页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第24页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第25页浏览型号BCM4414BH0E5035M06的Datasheet PDF文件第26页  
BCM4414xH0E5035yzz  
Dielectric Withstand  
ZHI_EQ1  
ZLO_EQ1  
The chassis of the BCM in a VIA package is required to be  
connected to Protective Earth when installed in the end  
application and must satisfy the requirements of IEC 60950-1 for  
Class I products.  
BCM®1  
R0_1  
VLO  
VHI  
ZLO_EQ2  
ZHI_EQ2  
BCM®2  
R0_2  
Summary  
The case is required to be connected to protective earth in the  
final installation.  
+
Load  
DC  
The construction of the BCM in a VIA package can be summarized  
by describing it as a “Class II” component installed in a  
“Class I” subassembly.  
ZLO_EQn  
BCM®n  
R0_n  
ZHI_EQn  
ChiP Isolation  
High voltage side  
Low voltage side  
SELV  
Figure 24 — BCM module array  
Fuse Selection  
In order to provide flexibility in configuring power systems, BCM in  
a VIA package modules are not internally fused. Input line fusing  
of BCM products is recommended at the system level to provide  
thermal protection in case of catastrophic failure.  
RI  
The fuse shall be selected by closely matching system  
requirements with the following characteristics:  
Figure 25 — BCM in a ChiP™ package before final assembly in the  
VIA package  
nCurrent rating  
(usually greater than maximum current of BCM module)  
nMaximum voltage rating  
HV VIA Isolation Drawing  
(usually greater than the maximum possible input voltage)  
nAmbient temperature  
nNominal melting I2t  
+HI  
-HI  
+LO  
-LO  
ChiP  
nRecommend fuse: see safety agency approvals (HI side)  
High voltage side  
Low voltage side  
SELV  
VIA HI Side Circuit  
VIA LO Side Circuit  
Reverse Operation  
RI  
BCM modules are capable of reverse power operation. Once the  
unit is started, energy will be transferred from the low-voltage  
side back to the high-voltage side whenever the low side voltage  
exceeds VHI • K. The module will continue operation in this fashion  
as long as no faults occur.  
FI  
BI  
PE  
The BCM4414xH0E5035yzz has not been qualified for continuous  
operation in a reverse power condition. However, fault protections  
that help to protect the module in forward operation will also  
protect the module in reverse operation.  
Figure 26 — BCM in a VIA package after final assembly  
Transient operation in reverse is expected in cases where there is  
significant energy storage on the low-voltage side and transient  
voltages appear on the high-voltage side.  
BCM® in a VIA™ Package  
Page 22 of 43  
Rev 1.0  
04/2019  
 复制成功!