欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM4414VD1E13A2T02 参数 Datasheet PDF下载

BCM4414VD1E13A2T02图片预览
型号: BCM4414VD1E13A2T02
PDF下载: 下载PDF文件 查看货源
内容描述: [DC DC CONVERTER 12V 1500W]
分类和应用:
文件页数/大小: 43 页 / 4056 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第4页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第5页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第6页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第7页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第9页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第10页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第11页浏览型号BCM4414VD1E13A2T02的Datasheet PDF文件第12页  
BCM4414xD1E13A2yzz  
Electrical Specifications (Cont.)  
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of  
-40°C TCASE 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.  
Attribute  
Symbol  
Conditions / Notes  
Min  
Typ  
Max  
Unit  
Powertrain Supervisory Limits Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side)  
• These supervisory limits are set in the internal controller and can be reconfigured or disabled through PMBus®.  
• When disabled, the powertrain protections presented in the previous table will intervene during fault events.  
HI Side Overvoltage Lockout  
Threshold  
VHI_OVLO+  
VHI_OVLO-  
VHI_OVLO_HYST  
tHI_OVLO  
420  
405  
434.5  
424  
10.5  
100  
226  
244  
15  
450  
440  
V
V
HI Side Overvoltage Recovery  
Threshold  
HI Side Overvoltage Lockout  
Hysteresis  
V
HI Side Overvoltage Lockout  
Response Time  
µs  
V
HI Side Undervoltage Lockout  
Threshold  
VHI_UVLO-  
200  
225  
250  
259  
HI Side Undervoltage Recovery  
Threshold  
VHI_UVLO+  
VHI_UVLO_HYST  
tHI_UVLO  
V
HI Side Undervoltage Lockout  
Hysteresis  
V
HI Side Undervoltage Lockout  
Response Time  
100  
µs  
From VHI_DC = VHI_UVLO+ to powertrain active, (i.e., one  
time startup delay from application of VHI_DC to VLO_DC  
HI Side Undervoltage Startup Delay  
LO Side Overcurrent Trip Threshold  
tHI_UVLO+_DELAY  
20  
ms  
)
ILO_OUT_OCP  
tLO_OUT_OCP  
tOTP+  
159  
168  
2
177  
A
LO Side Overcurrent  
Response Time Constant  
Effective internal RC filter  
Internal  
ms  
°C  
°C  
Overtemperature Shutdown  
Threshold  
125  
Overtemperature Recovery  
Threshold  
tOTP–  
Internal  
105  
110  
115  
C-Grade  
T-Grade  
-25  
-45  
Undertemperature Shutdown  
Threshold (Internal)  
tUTP  
°C  
s
Startup into a persistent fault condition. Non-latching  
fault detection given VHI_DC > VHI_UVLO+  
Undertemperature Restart Time  
tUTP_RESTART  
3
BCM® in a VIA™ Package  
Page 8 of 43  
Rev 1.7  
08/2020