 浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第2页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第3页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第4页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第5页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第7页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第8页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第9页浏览型号BCM384P120T1K5ACR的Datasheet PDF文件第10页  
BCM384x120y1K5ACz  
Electrical Specifications (Cont.)  
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C TINTERNAL  
125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.  
Attribute  
Symbol  
Conditions / Notes  
Min  
Typ  
Max  
Unit  
General Powetrain PRIMARY to SECONDARY Specification (Forward Direction) Cont.  
Effective Primary Capacitance  
(Internal)  
CPRI_INT  
CSEC_INT  
CSEC_OUT_EXT  
CSEC_OUT_AEXT  
Effective Value at 384 VPRI_DC  
Effective Value at 12 VSEC_DC  
0.37  
208  
µF  
µF  
µF  
Effective Secondary Capacitance  
(Internal)  
Effective Secondary Output  
Capacitance (External)  
Effective Secondary Output  
Capacitance (External)  
Excessive capacitance may drive module into SC  
protection  
1000  
CSEC_OUT_AEXT Max = N * 0.5 * CSEC_OUT_EXT MAX, where  
N = the number of units in parallel  
Protection PRIMARY to SECONDARY (Forward Direction)  
Startup into a persistent fault condition. Non-Latching  
fault detection given VPRI_DC > VPRI_UVLO+  
Auto Restart Time  
tAUTO_RESTART  
VPRI_OVLO+  
VPRI_OVLO-  
VPRI_OVLO_HYST  
tPRI_OVLO  
292.5  
420  
357.5  
450  
ms  
V
Primary Overvoltage Lockout  
Threshold  
434.5  
424  
10.5  
100  
221  
243  
15  
Primary Overvoltage Recovery  
Threshold  
410  
440  
V
Primary Overvoltage Lockout  
Hysteresis  
V
Primary Overvoltage Lockout  
Response Time  
µs  
V
Primary Undervoltage Lockout  
Threshold  
VPRI_UVLO-  
195  
225  
250  
255  
Primary Undervoltage Recovery  
Threshold  
VPRI_UVLO+  
VPRI_UVLO_HYST  
tPRI_UVLO  
V
Primary Undervoltage Lockout  
Hysteresis  
V
Primary Undervoltage Lockout  
Response Time  
100  
µs  
From VPRI_DC = VPRI_UVLO+ to powertrain active, EN  
Primary Undervoltage Startup Delay tPRI_UVLO+_DELAY floating, (i.e One time Startup delay form application  
of VPRI_DC to VSEC_DC  
20  
ms  
)
From powertrain active. Fast Current limit protection  
disabled during Soft-Start  
Primary Soft-Start Time  
tPRI_SOFT-START  
ISEC_OUT_OCP  
tSEC_OUT_OCP  
ISEC_OUT_SCP  
tSEC_OUT_SCP  
tOTP+  
1
170  
3
ms  
A
Secondary Output Overcurrent Trip  
Threshold  
135  
187  
210  
Secondary Output Overcurrent  
Response Time Constant  
Secondary Output Short Circuit  
Protection Trip Threshold  
Secondary Output Short Circuit  
Protection Response Time  
Overtemperature Shutdown  
Threshold  
Effective internal RC filter  
ms  
A
1
110  
3
µs  
°C  
°C  
°C  
s
Temperature sensor located inside controller IC  
125  
Overtemperature Recovery  
Threshold  
tOTP–  
105  
115  
-45  
Undertemperature Shutdown  
Threshold  
Temperature sensor located inside controller IC;  
Protection not available for M-Grade units.  
Startup into a persistent fault condition. Non-Latching  
fault detection given VPRI_DC > VPRI_UVLO+  
tUTP  
Undertemperature Restart Time  
tUTP_RESTART  
BCM® Bus Converter  
Page 6 of 25  
Rev 1.5  
vicorpower.com  