BCM3814x60E10A5yzz
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Parameter
Comments
Min
Max
80
Unit
V
+HI to –HI
-1
HI_DC or LO_DC slew rate
+LO to –LO
1
V/µs
V
-1
15
-0.3
10
V
EXT BIAS to SGND
0.15
5.5
5.5
3.6
A
SCL to SGND
-0.3
-0.3
-0.3
V
SDA to SGND
V
ADDR to SGND
V
Dielectric Withstand*
High Voltage Side to Case
See note below
Basic Insulation
1500
1500
N/A
VDC
VDC
VDC
High Voltage Side to
Low voltage Side
Basic Insulation
Low Voltage Side to Case
Functional Insulation
* The SELV side (-LO) is directly connected to the case of the BCM in a VIA package.
BCM® in a VIA Package
Page 4 of 39
Rev 1.4
09/2016
vicorpower.com
800 927.9474