BCM3814x60E10A5yzz
Operating Area
200
180
160
140
120
100
80
60
40
20
0
–60
–40 –20
0
20
40
60
80
100
120
Case Temperature ( °C)
36 – 60V
Figure 1 — Specified thermal operating area
1. The BCM in a VIA package is cooled through the non-pin-side case.
2. The thermal rating is based on typical measured device efficiency.
3. The case temperature in the graph is the measured temperature of the non-pin-side housing, such that the internal operating temperature
does not exceed 125°C.
2000
1750
1500
1250
1000
750
200
175
150
125
100
75
500
50
250
25
0
0
36 38 40 42 44 46 48 50 52 54 56 58 60
36 38 40 42 44 46 48 50 52 54 56 58 60
HI-Side Voltage (V)
HI-Side Voltage (V)
ILO_OUT_DC
ILO_OUT_PULSE
PLO_OUT_DC
PLO_OUT_PULSE
Figure 2 — Specified electrical operating area using rated RLO_HOT
110
100
90
80
70
60
50
40
30
20
10
0
0
20
40
60
80
100
LO Side-Current (% ILO_DC
)
Figure 3 — Specified HI-side start up into load current and external capacitance
BCM® in a VIA™ Package
Page 9 of 41
Rev 2.1
07/2020