BCM3814x60E10A5yzz
Application Characteristics
Temperature controlled via pin-side side cold plate, unless otherwise noted. All data presented in this section are collected from units processing power in the
forward direction (high-voltage side to low-voltage side). See associated figures for general trend data.
16
14
12
10
8
97.0
96.0
95.0
6
94.0
93.0
4
2
0
–40
–20
0
20
40
60
80
100
36 38 40 42 44 46 48 50 52 54 56 58 60
Case Temperature (ºC)
HI-Side Voltage (V)
VHI_DC
:
36V
54V
60V
TCASE
:
–40°C
25°C
70°C
Figure 4 — No-load power dissipation vs. VHI_DC
Figure 5 — Full-load efficiency vs. temperature
100
90
80
70
60
50
40
30
20
10
0
99
97
95
93
91
89
87
85
83
81
79
0
15
30
45
60
75
90 105 120 135 150
0
15
30
45
60
75
90 105 120 135 150
LO-Side Current (A)
LO-Side Current (A)
36V 54V
VHI_DC
:
VHI_DC:
36V
54V
60V
60V
Figure 6 — Efficiency at TCASE = –40°C
Figure 7 — Power dissipation at TCASE = –40°C
100
90
80
70
60
50
40
30
20
10
0
99
97
95
93
91
89
87
85
83
81
79
0
15
30
45
60
75
90 105 120 135 150
0
15
30
45
60
75
90 105 120 135 150
LO-Side Current (A)
LO-Side Current (A)
VHI_DC
:
36V
54V
60V
VHI_DC:
36V
54V
60V
Figure 8 — Efficiency at TCASE = 25°C
Figure 9 — Power dissipation at TCASE = 25°C
BCM® in a VIA™ Package
Page 14 of 41
Rev 2.1
07/2020