BCM3814x60E15A3yzz
READ_VIN Command (88h)
READ_POUT Command (96h)
If PAGE data byte is equal to (01h), command will return the BCM’s
HI side voltage in the following format:
If PAGE data byte is equal to (01h), command will return the BCM’s
LO side power in the following format:
VHI_ACTUAL = VHI_REPORTED • 10-1(V)
PLO_ACTUAL = PLO_REPORTED (W)
If PAGE data byte is equal to (00h), command will also return the
BCM’s LO side power.
READ_IIN Command (89h)
If PAGE data byte is equal to (01h), command will return the BCM’s
HI side current in the following format:
MFR_VIN_MIN Command (A0h),
MFR_VIN_MAX Command (A1h),
MFR_VOUT_MIN Command (A4h),
MFR_VOUT_MAX Command (A5h),
MFR_IOUT_MAX Command (A6h),
MFR_POUT_MAX Command (A7h)
IHI_ACTUAL = IHI_REPORTED • 10-2(A)
If PAGE data byte is equal (00h), command will also return the
BCM’s HI side current.
These values are set by the factory and indicate the device HI
side/LO side voltage and LO side current range and LO side
power capacity.
READ_VOUT Command (8Bh)
If PAGE data byte is equal to (01h), command will return the BCM’s
LO side voltage in the following format:
If the PAGE data byte is equal to (00h – 01h), commands will report
the rated BCM HI side voltage minimum and maximum in Volts,
LO side voltage minimum and maximum in Volts, LO side current
maximum in Amperes and LO side power maximum in Watts.
VLO_ACTUAL = VLO_REPORTED • 10-1(V)
READ_IOUT Command (8Ch)
If PAGE data byte is equal to (01h), command will return the BCM’s
LO side current in the following format:
ILO_ACTUAL = ILO_REPORTED • 10-2(A)
If PAGE data byte is equal (00h), command will also return the
BCM’s LO side current.
READ_TEMPERATURE_1 Command (8Dh)
If PAGE data byte is equal to (01h), command will return the BCM’s
temperature in the following format:
TACTUAL = TREPORTED (°C)
If PAGE data byte is equal (00h), command will also return the
BCM’s temperature.
BCM® in a VIA Package
Page 33 of 41
Rev 2.0
02/2018