欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM380x475y1K2A31 参数 Datasheet PDF下载

BCM380x475y1K2A31图片预览
型号: BCM380x475y1K2A31
PDF下载: 下载PDF文件 查看货源
内容描述: [Isolated Fixed-Ratio DC-DC Converter]
分类和应用:
文件页数/大小: 30 页 / 872 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM380x475y1K2A31的Datasheet PDF文件第19页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第20页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第21页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第22页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第24页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第25页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第26页浏览型号BCM380x475y1K2A31的Datasheet PDF文件第27页  
BCM6123xD1E5126yzz  
PMBus™ System Diagram  
-OUT  
BCM  
EN Control  
3.3V, at least 20mA  
when using 4xDISO  
SCL  
Ref to Digital Isolator  
datasheet for more details  
Digital Isolator  
3 kΩ  
VDD  
3 kΩ  
BCM EN  
5V EXT  
VDDB  
SEC-IN-A  
SEC-IN-B  
PRI-OUT-A  
PRI-OUT-B  
PRI-IN-C  
SER-IN  
SER-OUT  
-IN BCM  
TXD1’  
RXD1  
RXD4  
RXD3  
RXD2  
RXD1  
TXD4  
TXD3  
SEC-OUT-C  
VDD  
NC  
CP  
D
VCC  
PRI-COM  
SEC-COM  
SD  
RD  
Q
D
D44TL1A0 NC  
Q
NC  
SSTOP  
Flip-flop  
VDD  
Host  
µc  
SGND  
SDA  
SCL  
74LVC1G74DC  
10 kΩ  
PMBus  
FDG6318P  
R1  
R2  
10 kΩ  
SGND  
The PMBus communication enabled bus converter provides accurate telemetry monitoring and reporting, threshold and warning  
limits adjustment, in addition to corresponding status flags.  
The BCM internal µC is referenced to primary ground. The Digital Isolator allows UART communication interface with the host Digital  
Supervisor at typical speed of 750KHz across the isolation barrier. One of the advantages of the Digital Isolator is its low power  
consumption. Each transmission channel is able to draw its internal bias circuitry directly from the input signal being transmitted to  
the output with minimal to no signal distortion.  
The Digital Supervisor provides the host system µC with access to an array of up to 4 BCMs. This array is constantly polled for status  
by the Digital Supervisor. Direct communication to individual BCM is enabled by a page command. For example, the page (0x00)  
prior to a telemetry inquiry points to the Digital Supervisor data and pages (0x01 – 0x04) prior to a telemetry inquiry points to the  
array of BCMs connected data. The Digital Supervisor constantly polls the BCM data through the UART interface.  
The Digital Supervisor enables the PMBus compatible host interface with an operating bus speed of up to 400kHz. The Digital  
Supervisor follows the PMBus command structure and specification.  
Please refer to the Digital Supervisor data sheet for more details.  
BCM® Bus Converter  
Page 23 of 30  
Rev 1.1  
01/2017  
vicorpower.com  
800 927.9474  
 复制成功!