 浏览型号BCM352F125T300A00的Datasheet PDF文件第1页浏览型号BCM352F125T300A00的Datasheet PDF文件第3页浏览型号BCM352F125T300A00的Datasheet PDF文件第4页浏览型号BCM352F125T300A00的Datasheet PDF文件第5页浏览型号BCM352F125T300A00的Datasheet PDF文件第6页浏览型号BCM352F125T300A00的Datasheet PDF文件第7页浏览型号BCM352F125T300A00的Datasheet PDF文件第8页浏览型号BCM352F125T300A00的Datasheet PDF文件第9页  
BCM352 x 125 y 300A00  
CONTROL PIN SPECIFICATIONS  
ABSOLUTE MAXIMUM RATINGS  
See section 5.0 for further application details and guidelines.  
+IN to –IN . . . . . . . . . . . . . . . . . . . . . . . . -1.0 Vdc – +400 Vdc  
PC to –IN . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 Vdc – +20 Vdc  
TM to –IN . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 Vdc – +7 Vdc  
+IN/-IN to +OUT/-OUT . . . . . . . . . . . . . . . . . . . 4242 V (Hi Pot)  
+IN/-IN to +OUT/-OUT. . . . . . . . . . . . . . . . . . . 500 V (working)  
+OUT to –OUT . . . . . . . . . . . . . . . . . . . . . . -1.0 Vdc - +16 Vdc  
Temperature during reflow . . . . . . . . . . . . . . . . 245 °C (MSL 6)  
PC (BCM® Primary Control)  
The PC pin can enable and disable the BCM™ bus converter.  
When held below VPC_DIS the BCM module shall be disabled.  
When allowed to float with an impedance to –IN of greater  
than 50 kΩ the module will start. When connected to another  
bus converter PC pin, the modules will start simultaneously  
when enabled. The PC pin is capable of being driven high by  
an either external logic signal or internal pull up to 5 V (operat-  
ing).  
PACKAGE ORDERING INFORMATION  
TM (BCM® Temperature Monitor)  
4
3
2
1
A
B
C
D
A
B
C
D
E
The TM pin monitors the internal temperature of the module  
within an accuracy of +5/-5 °C. It has a room temperature  
setpoint of ~3.0 V and an approximate gain of 10 mV/°C. It  
can source up to 100 µA and may also be used as a “Power  
Good” flag to verify that the bus converter is operating.  
+Out  
-Out  
+In  
E
F
G
H
TM  
H
J
RSV  
PC  
J
K
L
K
+Out  
-Out  
L
M
N
P
R
T
M
N
P
R
T
-In  
Bottom View  
Signal  
Name  
Designation  
A1-E1, A2-E2  
L1-T1, L2-T2  
H1, H2  
J1, J2  
K1, K2  
+In  
–In  
TM  
RSV  
PC  
A3-D3, A4-D4,  
J3-M3, J4-M4  
E3-H3, E4-H4,  
N3-T3, N4-T4  
+Out  
–Out  
BCM® Bus Converter  
Page 2 of 18  
Rev 1.7  
vicorpower.com  
800 735.6200  