BCM352x110y300B00
Signal Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
Primary Control: PC
• The PC pin enables and disables the BCM. When held low, the BCM is disabled.
• In an array of BCM modules, PC pins should be interconnected to synchronize start up and permit start up into full load conditions.
• PC pin outputs 5V during normal operation. PC pin internal bias level drops to 2.5V during fault mode, provided VIN remains
in the valid range.
SIGNAL TYPE
STATE
ATTRIBUTE
PC voltage
SYMBOL
CONDITIONS / NOTES
MIN
TYP MAX UNIT
VPC
4.7
2.0
50
5.0
3.5
5.3
5.0
V
mA
µA
kΩ
pF
kΩ
ms
V
Regular
Operation
PC available current
PC source (current)
PC resistance (internal)
PC capacitance (internal)
PC load resistance
IPC_OP
IPC_EN
RPC_INT
CPC_INT
RPC_S
100
150
ANALOG
OUTPUT
Standby
Internal pull down resistor
To permit regular operation
50
400
Transition
Start Up
Start Up
4700
60
380
2.0
PC time to start
TON1
440
2.5
500
3.0
PC enable threshold
PC disable threshold
VPC_EN
VPC_DIS
Regular
Operation
1.95
V
Minimum time before attempting
re-enable
DIGITAL
INPUT /
OUTPUT
Standby
PC disable duration
TPC_DIS_T
1
s
PC threshold hysteresis
PC enable to VOUT time
PC disable to standby time
PC fault response time
VPC_HYSTER
TON2
TPC_DIS
TFR_PC
50
100
4
mV
µs
VIN = 352V for at least TON1 ms
From fault to PC = 2V
50
150
Transition
10
µs
100
µs
Temperature Monitor: TM
• The TM pin monitors the internal temperature of the controller IC within an accuracy of 5°C.
• Can be used as a “Power Good” flag to verify that the BCM module is operating.
• Is used to drive the internal comparator for Overtemperature Shutdown.
SIGNAL TYPE
STATE
ATTRIBUTE
TM voltage range
SYMBOL
CONDITIONS / NOTES
MIN
TYP MAX UNIT
VTM
VTM_AMB
ITM
2.12
4.04
3.05
100
V
V
TM voltage reference
TM available current
TM gain
TJ controller = 27°C
2.95
3.00
ANALOG
OUTPUT
Regular
Operation
µA
mV/°C
mV
pF
ATM
10
TM voltage ripple
TM capacitance (external)
TM fault response time
TM voltage
VTM_PP
CTM_EXT
TFR_TM
VTM_DIS
RTM_INT
CTM = 0pF, VIN = 352V, IOUT = 28.5A
From fault to TM = 1.5V
120
200
50
Transition
Standby
DIGITAL
INPUT /
OUTPUT
10
0
µs
V
TM pull down (internal)
Internal pull down resistor
25
40
50
kΩ
Reserved: RSV
Reserved for factory use. No connection should be made to this pin.
BCM® Bus Converter
Page 7 of 21
Rev 1.2
08/2016
vicorpower.com
800 927.9474