BCM352x110y300B00
Application Characteristics
The following values, typical of an application environment, are collected at TCASE = 25ºC unless otherwise noted. See associated figures for general trend data.
97.0
14
13
96.5
12
11
10
9
96.0
95.5
95.0
94.5
94.0
8
7
6
5
4
-40
-20
0
20
40
60
80
100
330 334 338 342 346 349 353 357 361
365
Case Temperature (ºC)
Input Voltage (V)
330 V
352 V
365 V
-40ºC
25ºC
100ºC
VIN:
Figure 3 — No load power dissipation vs. Vin
Figure 4 — Full load efficiency vs. temperature; Vin
98
94
90
86
82
78
74
70
35
30
25
20
15
10
5
0
0.0 2.8 5.6 8.4
14.0 16.8 19.6 22.4 25.2 28.0
0.0 2.8 5.6 8.4
11.2
11.2
14.0 16.8 19.6 22.4 25.2 28.0
Load Current (A)
Load Current (A)
VIN:
VIN:
330V
352V
365V
330V
352V
365V
Figure 5 — Efficiency at TCASE = -40°C
Figure 6 — Power dissipation at TCASE = -40°C
98
94
90
86
82
78
74
70
35
30
25
20
15
10
5
0
0.0 2.8 5.6 8.4
14.0 16.8 19.6 22.4 25.2 28.0
0.0 2.8 5.6 8.4
11.2
11.2
14.0 16.8 19.6 22.4 25.2 28.0
Load Current (A)
Load Current (A)
VIN:
VIN:
330V
352V
365V
330V
352V
365V
Figure 7 — Efficiency at TCASE = 25°C
Figure 8 — Power dissipation at TCASE = 25°C
BCM® Bus Converter
Page 9 of 21
Rev 1.2
08/2016
vicorpower.com
800 927.9474