Set Up  
The evaluation board should be set up as follows.  
Note: Care should be taken to avoid reversing polarities if connecting to the opposite (solder) side of the board.  
+IN, –IN  
Connect a high-quality, low-noise power supply to the +IN and –IN terminals of the evaluation board.  
The interconnect leads should be heavy gauge and as short as possible. Additional capacitance may  
have to be added on the evaluation board to make up for impedances in the interconnect leads as  
well as deficiencies in the source. It is important to remember that noise from the source, as well as  
any input source voltage drops, will appear at the output of the BCM® multiplied by its K factor. Test  
points 4 (–IN) and 5 (+IN) can be used to monitor the input and are located on the PCB adjacent to the  
input terminals.  
+ OUT, –OUT  
An electronic or passive load should be connected to +OUT and –OUT terminals of the evaluation  
board with short heavy-gauge leads. Most commercially available electronic loads do not have current  
slew rates capable of fully exercising the BCM. The evaluation board can be connected directly to  
the application for which the BCM is intended. However, the interconnect impedances between  
the evaluation board and the application can greatly affect the transient response. For applications  
where transient response is critical, the user should consider mounting the BCM directly to the target  
application PCB. Test points 6 (–OUT) and 7 (+OUT) can be used to monitor the output and are located  
on the PCB adjacent to the output terminals.  
Output Voltage Measurement Jack (J1)  
This connector is provided to make accurate measurements of the output voltage of the BCM. Many  
types of scope probes may be directly connected to this point if the probe is equipped with a removable  
plastic sheath. To avoid creating ground loops when making measurements of the output or input  
voltage, these measurements should be made separately.  
Paralleling  
The paralleling and current sharing capability of the devices can be demonstrated by stacking multiple  
evaluation boards and interconnecting the inputs and outputs with standoffs of sufficient current  
handling capability to create a 3-dimensional array. See Figure 3. When paralleling BCMs, the PC ports  
should be connected together to ensure the outputs turn on simultaneously.  
UG:001  