Configuration Options
RECOMMENDED LAND PATTERN
(NO GROUNDING CLIPS)
TOP SIDE SHOWN
NOTES:
1. MAINTAIN 3.50 [0.138] DIA. KEEP-OUT ZONE
FREE OF COPPER, ALL PCB LAYERS.
2. (A) MINIMUM RECOMMENDED PITCH IS 39.50 [1.555],
THIS PROVIDES 7.00 [0.275] COMPONENT
EDGE-TO-EDGE SPACING, AND 0.50 [0.020]
CLEARANCE BETWEEN VICOR HEAT SINKS.
(B) MINIMUM RECOMMENDED PITCH IS 41.00 [1.614],
THIS PROVIDES 8.50 [0.334] COMPONENT
EDGE-TO-EDGE SPACING, AND 2.00 [0.079]
CLEARANCE BETWEEN VICOR HEAT SINKS.
3. V•I CHIP™ MODULE LAND PATTERN SHOWN FOR REFERENCE ONLY;
ACTUAL LAND PATTERN MAY DIFFER.
DIMENSIONS FROM EDGES OF LAND PATTERN
TO PUSH-PIN HOLES WILL BE THE SAME FOR
ALL FULL SIZE V•ICHIP PRODUCTS.
4. RoHS COMPLIANT PER CST-0001 LATEST REVISION.
5. UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE MM [INCH].
TOLERANCES ARE:
X.X [X.XX] = ±0.3 [0.01]
X.XX [X.XXX] = ±0.13 [0.005]
6. PLATED THROUGH HOLES FOR GROUNDING CLIPS (33855)
SHOWN FOR REFERENCE. HEAT SINK ORIENTATION AND
DEVICE PITCH WILL DICTATE FINAL GROUNDING SOLUTION.
RECOMMENDED LAND PATTERN
(With GROUNDING CLIPS)
TOP SIDE SHOWN
Figure 19
— Hole location for push pin heat sink relative to V
•
I Chip™ module
vicorpower.com
800-735-6200
BCM™ Bus Converter
B048F096T24
Rev. 4.9
Page 9 of 12