欢迎访问ic37.com |
会员登录 免费注册
发布采购

B048T240T30A 参数 Datasheet PDF下载

B048T240T30A图片预览
型号: B048T240T30A
PDF下载: 下载PDF文件 查看货源
内容描述: [BCM BUS CONVERTER 24V 300W]
分类和应用:
文件页数/大小: 18 页 / 2477 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号B048T240T30A的Datasheet PDF文件第10页浏览型号B048T240T30A的Datasheet PDF文件第11页浏览型号B048T240T30A的Datasheet PDF文件第12页浏览型号B048T240T30A的Datasheet PDF文件第13页浏览型号B048T240T30A的Datasheet PDF文件第15页浏览型号B048T240T30A的Datasheet PDF文件第16页浏览型号B048T240T30A的Datasheet PDF文件第17页浏览型号B048T240T30A的Datasheet PDF文件第18页  
B048x240y30A  
Not Recommended for New Designs  
12.0 CURRENT SHARING  
13.0 FUSE SELECTION  
The performance of the SAC™ topology is based on efficient  
transfer of energy through a transformer without the need of  
closed loop control. For this reason, the transfer characteristic  
can be approximated by an ideal transformer with a positive  
temperature coefficient series resistance.  
In order to provide flexibility in configuring power systems  
VI Chip® modules are not internally fused. Input line fusing  
of VI Chip products is recommended at system level to provide  
thermal protection in case of catastrophic failure.  
The fuse shall be selected by closely matching system  
requirements with the following characteristics:  
This type of characteristic is close to the impedance  
characteristic of a DC power distribution system both in  
dynamic (AC) behavior and for steady state (DC) operation.  
• Current rating (usually greater than maximum current  
of BCM module)  
When multiple BCM modules of a given part number are  
connected in an array they will inherently share the load  
current according to the equivalent impedance divider that the  
system implements from the power source to the point of load.  
• Maximum voltage rating (usually greater than the maximum  
possible input voltage)  
• Ambient temperature  
• Nominal melting I2t  
• Recommend fuse: <= 10A Littlefuse Nano2 Fuse.  
Some general recommendations to achieve matched array  
impedances include:  
• Dedicate common copper planes within the PCB  
to deliver and return the current to the modules.  
14.0 REVERSE OPERATION  
BCM® modules are capable of reverse power operation. Once  
the unit is started, energy will be transferred from secondary  
back to the primary whenever the secondary voltage exceeds  
VIN • K. The module will continue operation in this fashion for  
as long as no faults occur.  
• Provide as symmetric a PCB layout as possible among modules  
• Apply same input / output filters (if present) to each unit.  
For further details see AN:016 Using BCM Bus Converters  
in High Power Arrays.  
The B048x240y30A has not been qualified for continuous  
operation in a reverse power condition. Furthermore fault  
protections which help protect the module in forward  
operation will not fully protect the module in reverse  
operation.  
ZIN_EQ1  
ZOUT_EQ1  
BCM®1  
R0_1  
Vout  
Vin  
Transient operation in reverse is expected in cases where there  
is significant energy storage on the output and transient  
voltages appear on the input. Transient reverse power  
operation of less than 10 ms, 10% duty cycle is permitted and  
has been qualified to cover these cases.  
ZOUT_EQ2  
ZIN_EQ2  
BCM®2  
R0_2  
+
Load  
DC  
ZOUT_EQn  
BCM®n  
R0_n  
ZIN_EQn  
Figure 16 BCM module array  
BCM® Bus Converter  
Page 14 of 18  
Rev 1.1  
vicorpower.com  
800 927.9474  
11/2014  
 复制成功!