欢迎访问ic37.com |
会员登录 免费注册
发布采购

0154008DR 参数 Datasheet PDF下载

0154008DR图片预览
型号: 0154008DR
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Converter Evaluation Board]
分类和应用:
文件页数/大小: 14 页 / 2656 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号0154008DR的Datasheet PDF文件第1页浏览型号0154008DR的Datasheet PDF文件第3页浏览型号0154008DR的Datasheet PDF文件第4页浏览型号0154008DR的Datasheet PDF文件第5页浏览型号0154008DR的Datasheet PDF文件第6页浏览型号0154008DR的Datasheet PDF文件第7页浏览型号0154008DR的Datasheet PDF文件第8页浏览型号0154008DR的Datasheet PDF文件第9页  
Cool-Power® PI31xx Series Product Description  
The PI31xx operates over a wide range input, delivering 50 W or 60 W output power  
depending on the individual model number. The PI31xx Series is available in a space  
saving surface mountable 0.87” x 0.65” x 0.265” Power –System –in – a – Package (PSiP),  
achieving ~50% space reduction versus alternative solutions.  
The switching frequency of 900kHz allows for small input and output filter components  
which further reduces the total size and cost of the overall system solution. The output  
voltage is sensed and fed back to the internal controller using a proprietary isolated  
magnetic feedback scheme which allows for high bandwidth and good common mode  
noise immunity.  
The PI31xx Series requires no external feedback compensation and offers a total  
solution with a minimum number of external components. A rich feature set is  
offered, including + 10%, -20% output voltage trim capability (depending on the model  
number), remote enable, over-voltage protection, adjustable soꢀ-start, over-current  
protection with auto-restart to protect against both short circuit and overload and over  
and under input voltage lockout. A unique temperature monitor and protection circuit  
is included that provides an analog voltage proportional to the internal die temperature,  
as well as over temperature shutdown, restart and over temperature fault alarm signal.  
Board Connections  
1. Connect Test Equipment  
a.Connect the input DC power supply to the target board as shown in Figure 6.  
The negative terminal should be wired to –IN and the positive terminal should  
connect to the positive terminal of the DMM wired as a DC Ammeter. Be sure  
that the proper sized wires are used to allow minimum voltage drop for a  
maximum input current of up to 4 A. Use ring lugs mated to the included  
fasteners on the evaluation board. If your input power supply has remote sense  
capability, it can be wired to the INN and INP test points if desired. Connect the  
positive terminal of the DMM to the +IN lug on the evaluation board.  
b.Connect the primary side DMM (for measuring the input voltage) to INN and  
INP respectively.  
c.Connect the oscilloscope as shown in Figure 6 if you are planning to measure  
both primary and secondary signals at the same time. If you do not have an  
isolated differential amplifier, it is important to note that simultaneous  
measurement of both primary and secondary referenced signals using an  
oscilloscope with a grounded chassis is not recommended, as it will short circuit  
the primary to secondary isolation barrier. Floating the oscilloscope is also not  
recommended due to the large capacitance introduced by this long standing  
practice. The best practice is to use an isolated differential amplifier or use an  
oscilloscope with isolated channels. That is, the input returns are isolated from  
each other and earth ground.  
d. Connect the output DC DMM to the test points OUTN and OUTP. These test  
points are done in a Kelvin type manner so that they have no high current  
flowing in them.  
e. Connect the DC Load to the output lugs OUT+ and OUT-. It is critical for this  
connection to be low inductance.  
UG:301  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 2