FX-104 Frequency Translator
Outline Drawing
Pin Out
Pin
Symbol
Function
1
CLKIN
Input Frequency - The FX-104 series AC couples the input, this means the unit is capable of
handling HCMOS, LvHCMOS, PECL and LvPECL input signals.
(For Input Frequencies below 1 MHz only HCMOS and LvHCMOS are supported)
2
3
GND
Ground
LD
Lock Detect
(output)
Logic “1” indicates a locked condition
Logic “0” indicates that no input signal is present or the input signal has moved out of the
lock range.
4
Monitor
PLL/ VCXO control voltage
(Output)
Under locked conditions, should be >0.3V and <3.0V for the 3.3 volt option or >0.5V and
<4.5V for the 5 volt option. Input frequency may be out of range if voltage exceeds these limits.
5
6
7
8
---
NC
Missing
No Connection
Ground
GND
Enable
Disable
No connect
Logic “0”
=
=
Output enabled
Output disabled
9
Out
COUT
NC
Output
10
11
12
13
14
15
16
Complementary Output
No Connection
Select A
Select B
NC
Do not Exceed Vcc
Do not Exceed Vcc
No Connection
GND
Vcc
Ground
Power Supply Voltage (5 Vdc or 3.3Vdc)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web: www.vectron.com