C-TYPE Data Sheet
Enable/Disable Functional Description
Under normal operation the Enable/Disable is left open or set to a logic high state. When the E/D is set to a
logic low, the oscillator stops and the output is in a high impedance state. This helps reduce power
consumption as well as facilitating board testing and troubleshooting.
Tri-state Functional Description
Under normal operation the tri-state is left open or set to a logic high state. When the tri-state is set to a
logic low, the oscillator remains active but the output buffer is in a high impedance state. This helps facilitate
board testing and troubleshooting.
Table 3. Outline Diagrams, Pad Layout and Pin Out
Pin #
Symbol
E/D or NC
GND
Function
Tri-state, Enable/Disable or NC
Electrical and Case Ground
Output Frequency
1
2
3
4
fO
VDD
Supply Voltage
Contact Pads are gold over nickel
Figure 9, Package drawing
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail vectron@vectron.com