Table 5. Environmental Compliance
Parameter
PreHeat Time
Ramp Up
Time Above 217°C
Time To Peak Temperature
Time At 260°C
Ramp Down
Symbol
t
S
R
UP
t
L
t
AMP-B
t
P
R
DN
Value
60 sec Min, 180 sec Max
3°C/sec Max
60 sec Min, 150 sec Max
480 sec Max
20 sec Min, 40 sec Max
6°C/sec Max
The device has been qualified to meet the JEDEC
standard for Pb-Free assembly. The temperatures and
time intervals listed are based on the Pb-Free small
body requirements. The temperatures refer to the
topside of the package, measured on the package
body surface. The CD-700 device is hermetically sealed
so an aqueous wash is not an issue.
Figure 10. Suggested IR Profile
Tape and Reel
Figure 11. Tape and Reel
Table 6. Tape and Reel Information
Tape Dimensions (mm)
Reel Dimensions (mm)
A
16
B
7.5
C
1.5
D
4
E
8
F
1.5
G
20.2
H
13
I
50
J
6
K
16.4
L
178
#/Reel
200
Page 9 of 11
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com