US1010-33
ABSOLUTE MAXIMUM RATINGS
Input Voltage (Vin) .................................................................. 7V
Power Dissipation ............................................ Internally Limited
Storage Temperature Range .............................. -65°C TO 150°C
Operating Junction Temperature Range .................. 0°C TO 150°C
PACKAGE INFORMATION
2 PIN PLASTIC TO252 ( D ) 3 PIN PLASTIC SOT223 ( Y )
2 PIN POWER FLEX ( P )
3 PIN PLASTIC SOT223 ( Y )
TOP VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
3
3
Vin
Vin
1
2
3
4
8
7
6
5
Tab is
Vout
Vin
NC
Vout
Vout
Vout
Vout
3
2
1
Vin
Tab is
Vout
Tab is
Vout
Vout
Gnd
4
4
NC
Gnd
1
1
Gnd
Gnd
qJA=70°C/W for 0.5" Sq pad
qJA=90°C/W for 0.4" Sq pad
qJA=70°C/W for 0.5" Sq pad
qJA=55°C/W for 1" Sq pad
ELECTRICAL SPECIFICATIONS
Unless otherwise specified, these specifications apply over, Cin=1uF, Vin=5V,Cout=10uF, and Tj=0 to 125°C.Typical
values refer to Tj=25°C.
PARAMETER
SYM TEST CONDITION
MIN
TYP
MAX UNITS
Output Voltage
Vo
Io=10mA,Tj=25°C
Io=10mA
3.267 3.300 3.333
3.235 3.300 3.365
V
Line Regulation
Io=10mA,4.75V<Vin<7V
10mA<Io<1A
Io=1A
7
17
1.3
mV
mV
V
Load Regulation (Note 1)
Dropout Voltage (Note 2)
Current Limit
dVo=100mV
1.1
A
Thermal Regulation
Ripple Rejection
30 mS PULSE, Io=1A
f=120HZ ,Co=25uF Tan
Io=0.5A
0.01
70
0.02
1
%/W
dB
60
Temperature Stability
Long Term Stability
RMS Output Noise
Io=10mA
Tj=125°C,1000 Hrs
Tj=25°C 10hz<f<10khz
0.5
0.3
0.003
%
%
%Vo
Note 1 : Low duty cycle pulse testing with Kelvin connections are required in order to maintain accurate data.
Note 2 : Drop-out voltage is defined as the minimum differential voltage between Vin and Vout required to maintain
regulation at Vout. It is measured when the output voltage drops 1% below its nominal value.
Rev. 1.2
10/30/00
2-2