22-26GHz High Power Amplifier
Application note
CHA5093
The given DC Bias condition in table or curves are for optimum output power.
To optimize the gain a drain voltage of 5V could be apply. With this biasing point , the
output power at 1dB compression decreases by around 1dBm.
The curves below show typical jig measurements versus drain & gate voltages.
24
22
20
18
16
14
12
10
8
6
4
2
0
20
22
24
26
28
30
Frequency (GHz)
Gain with Vd=5V, Vg=-0,4V
Gain with Vd=5V, Vg=-0,2V
Gain with Vd=6V, Vg=-0,4V
Ref. : DSCHA50930129 -09 May-00
7/8
Specifications subject to change without notice
Route Départementale 128 , B.P.46 - 91401 ORSAY Cedex - FRANCE
Tel.: +33 (0)1 69 33 03 08 - Fax : +33 (0)1 69 33 03 09