Operating and Storage Temperature Range,
T
J
,T
STG
NOTES:
-55 TO +150
1. Recommended mounting position is to bolt down on heatsink with silicone thermal compound
for maximum heat transfer with #6 screw.
2. Units Mounted in free air, no heatsink, P.C.B at 0.375”(9.5mm) lead length with 0.5
×
0.5”
(12
×
12mm)copper pads.
3. Units Mounted on a 3.0
×
3.0”
×
0.11” thick (7.5
×
7.5
×
0.3cm) AL plate heatsink.
RATING AND CHARACTERISTIC CURVES
GBU8A THRU GBU8K
Fig. 1-DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
Fig. 2-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER ELEMENT
Fig. 3-TYPICAL REVERSE CHARACTERISTICS
Fig. 4- MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT