854678
70 MHz SAW Filter
Product Compliance Information
ESD Sensitivity Ratings
Solderability
Compatible with both lead-free (260°C maximum
reflow temperature) and tin/lead (245°C maximum
reflow temperature) soldering processes.
Caution! ESD-Sensitive Device
Refer to Soldering Profile for recommended guidelines.
ESD Rating: Class 1A
Value:
Test:
Passes ≥ 300 V to < 350 V
RoHs Compliance
Electrostatic Discharge Sensitivity Testing,
Human Body Model (HBM) - component level
Standard: ESDA/JEDEC JS-001-2012
This part is compliant with EU 2002/95/EC RoHS
directive (Restrictions on the Use of Certain
Hazardous Substances in Electrical and Electronic
Equipment).
ESD Rating: Class B
Value:
Test:
Standard:
Passes ≥ 200 V to 250 V
This product also has the following attributes:
Machine Model (MM)
•
•
•
•
•
•
Lead Free
Halogen Free (Chlorine, Bromine)
Antimony Free
TBBP-A (C15H12Br402) Free
PFOS Free
SVHC Free
JEDEC Standard JESD22-A115
MSL Rating
Not applicable. Hermetic package.
Contact Information
For the latest specifications, additional product information, worldwide sales and distribution locations, and
information about TriQuint:
Web: www.triquint.com
Email: info-sales@tqs.com
Tel:
Fax:
+1.407.886.8860
+1.407.886.7061
For technical questions and application information: Email: flapplication.engineering@tqs.com
Important Notice
The information contained herein is believed to be reliable. TriQuint makes no warranties regarding the information
contained herein. TriQuint assumes no responsibility or liability whatsoever for any of the information contained
herein. TriQuint assumes no responsibility or liability whatsoever for the use of the information contained herein.
The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated
with such information is entirely with the user. All information contained herein is subject to change without notice.
Customers should obtain and verify the latest relevant information before placing orders for TriQuint products. The
information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any
patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or
anything described by such information.
TriQuint products are not warranted or authorized for use as critical components in medical, life-saving, or life-
sustaining applications, or other applications where a failure would reasonably be expected to cause severe
personal injury or death.
Data Sheet: Rev - 06-27-2013
Disclaimer: Subject to change without notice
- 6 of 6 -
© 2013 TriQuint