Tripath Technology, Inc. – Technical Information
TPS4100A Pinout
PIN
1
2, 4, 6, 8
3, 5, 7, 9
10
NAME/FUNCTION TYPE
SLEEPB
Y1, Y2, Y3, Y4
Y1B, Y2B, Y3B, Y4B
MUTEB
DESCRIPTION
INPUT (L) Logic input, ACTIVE LOW. Setting SLEEP to low puts the TPS4100A in sleep
mode. Input range is 0 to 5V with 3.3V compliant inputs.
INPUT (L) Non-inverted switching modulator inputs.
INPUT (L) Inverted switching modulator inputs.
INPUT (L) Logic Input, ACTIVE LOW. Setting MUTE to low puts the device in mute mode.
Typically driven by external power supply or microcontroller. Input range is 0 to
5V with 3.3V compliant inputs.
INPUT (L) Logic input, ACTIVE HIGH. Enables Analog Mode operation. Typically driven
by Tripath controller. Input range is 0 to 5V with 3.3V compliant inputs.
OUTPUT
On chip 5V regulator bypass capacitor connection
11
AM
12
12
13, 14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
5VGEN
HMUTEB
AGND
CPUMP
OUT4P
VPP4
PGND
OUT4N
OUT3N
VPP3
OUT3P
FAULT
OUT2P
VPP2
OUT2N
OUT1N
PGND
VPP1
OUT1P
DCAP
PGND
OUTPUT (L) Logic output, ACTIVE LOW. HMUTEB low indicates TPS4100A is in mute
mode
GND
Analog ground
OUTPUT Charge pump output capacitor
OUTPUT Positive Output Channel 4
POWER
GND
OUTPUT
OUTPUT
POWER
OUTPUT
Positive Supply Voltage Channel 4
Power Ground for Outputs 3 and 4
Negative Output Channel 4
Negative Output Channel 3
Positive Supply Voltage Channel 3
Positive Output Channel 3
OUTPUT (L) Open Drain Logic Output, ACTIVE HIGH. FAULT high indicates fault condition.
OUTPUT
POWER
OUTPUT
OUTPUT
GND
POWER
OUTPUT
GND
Positive Output Channel 2
Positive Supply Voltage Channel 2
Negative Output Channel 2
Negative Output Channel 1
Power Ground for Outputs 1 and 2
Positive Supply Voltage Channel 1
Positive Output Channel 1
Power Ground
OUTPUT Oscillator output for driving external charge pump circuit
5
TPS4100A – KL/Rev. 1.1/11.05